Mostrar registro simples

dc.contributor.authorDexheimer Neto, Felippe Leopoldopt_BR
dc.contributor.authorAndrade, Juliana Mara Stormovski dept_BR
dc.contributor.authorRaupp, Ana Carolina Tabajarapt_BR
dc.contributor.authorTownsend, Raquel da Silvapt_BR
dc.contributor.authorBeltrami, Fabiana Gabept_BR
dc.contributor.authorBrisson, Hélènept_BR
dc.contributor.authorLu, Qinpt_BR
dc.contributor.authorDalcin, Paulo de Tarso Rothpt_BR
dc.date.accessioned2015-04-15T01:58:15Zpt_BR
dc.date.issued2015pt_BR
dc.identifier.issn1806-3713pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/115345pt_BR
dc.description.abstractObjetivo: O ultrassom pulmonar (USP) à beira do leito é uma técnica de imagem não invasiva e prontamente disponível que pode complementar a avaliação clínica. O protocolo Bedside Lung Ultrasound in Emergency (BLUE, ultrassom pulmonar à beira do leito em situações de emergência) demonstrou elevado rendimento diagnóstico em pacientes com insuficiência respiratória aguda (IRpA). Recentemente, um programa de treinamento em USP à beira do leito foi implementado na nossa UTI. O objetivo deste estudo foi avaliar a acurácia do USP baseado no protocolo BLUE, quando realizado por médicos com habilidades básicas em ultrassonografia, para orientar o diagnóstico de IRpA. Métodos: Ao longo de um ano, todos os pacientes adultos consecutivos respirando espontaneamente admitidos na UTI por IRpA foram prospectivamente inclusos. Após treinamento, 4 operadores com habilidades básicas em ultrassonografia realizaram o USP em até 20 minutos após a admissão na UTI, cegados para a história do paciente. Os diagnósticos do USP foram comparados aos diagnósticos da equipe assistente ao final da internação na UTI (padrão-ouro). Resultados: Foram inclusos na análise 37 pacientes (média etária: 73,2 ± 14,7 anos; APACHE II: 19,2 ± 7,3). O diagnóstico do USP demonstrou concordância com o diagnóstico final em 84% dos casos (kappa total: 0,81). As causas mais comuns de IRpA foram pneumonia (n = 17) e edema pulmonar cardiogênico (n = 15). A sensibilidade e a especificidade do USP comparado ao diagnóstico final foram de 88% e 90% para pneumonia e de 86% e 87% para edema pulmonar cardiogênico, respectivamente. Conclusões: O USP baseado no protocolo BLUE foi reproduzível por médicos com habilidades básicas em ultrassonografia e acurado para o diagnóstico de pneumonia e de edema pulmonar cardiogênico.pt_BR
dc.description.abstractObjective: Bedside lung ultrasound (LUS) is a noninvasive, readily available imaging modality that can complement clinical evaluation. The Bedside Lung Ultrasound in Emergency (BLUE) protocol has demonstrated a high diagnostic accuracy in patients with acute respiratory failure (ARF). Recently, bedside LUS has been added to the medical training program of our ICU. The aim of this study was to investigate the accuracy of LUS based on the BLUE protocol, when performed by physicians who are not ultrasound experts, to guide the diagnosis of ARF. Methods: Over a one-year period, all spontaneously breathing adult patients consecutively admitted to the ICU for ARF were prospectively included. After training, 4 non-ultrasound experts performed LUS within 20 minutes of patient admission. They were blinded to patient medical history. LUS diagnosis was compared with the final clinical diagnosis made by the ICU team before patients were discharged from the ICU (gold standard). Results: Thirty-seven patients were included in the analysis (mean age, 73.2 ± 14.7 years; APACHE II, 19.2 ± 7.3). LUS diagnosis had a good agreement with the final diagnosis in 84% of patients (overall kappa, 0.81). The most common etiologies for ARF were pneumonia (n = 17) and hemodynamic lung edema (n = 15). The sensitivity and specificity of LUS as measured against the final diagnosis were, respectively, 88% and 90% for pneumonia and 86% and 87% for hemodynamic lung edema. Conclusions: LUS based on the BLUE protocol was reproducible by physicians who are not ultrasound experts and accurate for the diagnosis of pneumonia and hemodynamic lung edema.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.relation.ispartofJornal brasileiro de pneumologia. Brasília. Vol. 41, n. 1 (jan./fev 2015), p. 58-64pt_BR
dc.rightsOpen Accessen
dc.subjectInsuficiência respiratória agudapt_BR
dc.subjectUltrasonography, interventionalen
dc.subjectVentilação pulmonarpt_BR
dc.subjectRespiratory insufficiencyen
dc.subjectIntensive care unitsen
dc.titleAcurácia diagnóstica do protocolo de ultrassom pulmonar à beira do leito em situações de emergência para diagnóstico de insuficiência respiratória aguda em pacientes com ventilação espontâneapt_BR
dc.title.alternativeDiagnostic accuracy of the bedside lung ultrasound in emergency protocol for the diagnosis of acute respiratory failure in spontaneously breathing patients en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000963351pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples