Mostrar registro simples

dc.contributor.advisorSilveira, Heraldo Luis Dias dapt_BR
dc.contributor.authorFontana, Mathias Pantept_BR
dc.date.accessioned2016-04-14T02:06:49Zpt_BR
dc.date.issued2010pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/138204pt_BR
dc.description.abstractO objetivo desse estudo foi avaliar a influência da resolução de voxel na capacidade de detecção do segundo canal radicular em incisivos mandibulares por meio da Tomografia Computadorizada Cone Beam (CBCT). Foram analisadas imagens tomográficas de 59 incisivos mandibulares em um aparelho i-CAT (Imaging Sciences International, Inc, Hatfield, PA; 120 KVp, 3-8 mA). Secções axiais, frontais e sagitais foram obtidas de acordo com 2 protocolos dependendo da resolução de voxel desejada: 0.3- e 0.2-mm. As imagens foram analisadas com o software i-Cat Vision (Imaging Sciences International, Inc) por um dentista especialista em radiologia cegado e previamente calibrado que classificou os dentes em cinco categorias: (1) certamente não há segundo canal; (2) possivelmente não há segundo canal; (3) é incerta a presença do segundo canal; (4) possivelmente há o segundo canal; (5) certamente há o segundo canal. Foi aplicado o teste Kappa ponderado (utilizando pesos lineares) que apresentou um resultado de 0,42, o que indica um baixo nível de concordância entre os dois grupos. Concluiu-se que o uso da resolução de voxel 0.2mm proporciona maior nível de certeza na detecção do segundo canal radicular em incisivos mandibulares quando comparada ao voxel 0.3mm (30,5% e 13,6% respectivamente).pt_BR
dc.description.abstractThe aim of this study was to evaluate the influence of voxel resolution in the diagnostic ability of Cone Beam Computed Tomography (CBCT) to detect second root canal in mandibular incisors. For that purpose, 59 mandibular incisors were viewed through i-Cat tomograph (Imaging Sciences International, Inc, Hatfield, PA; 120 KVp, 3-8 mA). Axial, frontal and sagittal sections were obtained following two protocols in which the variation was the voxel resolution (0.3 and 0.2mm). A calibrated oral radiologist blinded to the protocol assessed the images through the i-Cat Vison software (Imaging Sciences International, Inc) and classified the theet in five categories: (1) certainly there is no second canal; (2) probably there is no second canal; (3) the presence of the second canal is ucertain; (4) probably there is a second canal; (5) certainly there is a second canal. The weighted kappa test (using linear weights) was 0.42 which indicates a low concordance level between the groups. It was concluded that voxel resolution 0.2 increases certain on the second root canal detection in mandibular incisors when compared to voxel 0.3 (30,5% e13,6% respectively).en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectCone beam computed tomographyen
dc.subjectRadiografia computadorizadapt_BR
dc.subjectCanais radiculares : Anatomiapt_BR
dc.subjectRoot canal morphologyen
dc.subjectVoxel resolutionen
dc.titleInfluência da resolução de voxel na capacidade de detecção do segundo canal em incisivos mandibulares utilizando a Tomografia Cone Beampt_BR
dc.typeTrabalho de conclusão de especializaçãopt_BR
dc.identifier.nrb000747899pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2010pt_BR
dc.degree.levelespecializaçãopt_BR
dc.degree.specializationCurso de Especialização em Radiologia Odontológica e Imaginologiapt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples