Mostrar registro simples

dc.contributor.advisorFontanella, Vania Regina Camargopt_BR
dc.contributor.authorGravina, Bruna Lealpt_BR
dc.date.accessioned2016-08-13T02:15:44Zpt_BR
dc.date.issued2016pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/147193pt_BR
dc.description.abstractA tomografia computadorizada por feixe cônico (TCFC) foi introduzida recentemente como uma ferramenta útil para o diagnóstico e planejamento de tratamentos na Odontologia. Apesar da crescente aplicabilidade na prática odontológica, a TCFC apresenta algumas desvantagens, como os artefatos, que se destacam como o principal fator na perda de qualidade diagnóstica deste exame. Estes artefatos são discrepâncias entre a imagem visual reconstruída e o conteúdo real do objeto, e eventualmente impossibilitando o diagnóstico. Além disso, estruturas inexistentes podem aparecer dentro das imagens adquiridas. Tais estruturas podem ocorrer devido a diferentes fatores, como movimentação do paciente durante a varredura, captura de imagem e processo de reconstrução. Para aperfeiçoar a qualidade da imagem, é necessário entender os tipos de artefatos e suas consequências para a prática clínica do cirurgião-dentista. O objetivo do presente estudo é revisar a literatura quanto a publicações relativas a artefatos em tomografia computadorizada por feixe cônico (TCFC). Foram encontrados 20 artigos que preencheram os critérios de inclusão os quais foram divididos de acordo com as áreas da Odontologia: Endodontia, Prótese, Cirurgia e Traumatologia Buco-maxilo Faciais, Implantodontia e Ortodontia. Todos os materiais odontológicos geram alguma intensidade de artefatos. Pode-se concluir que o uso da TCFC deve ser cauteloso, sua indicação deve ser prudente e não pode ser justificada onde não há benefício direto para o paciente.pt_BR
dc.description.abstractCone beam computed tomography (CBCT) has recently been introduced as a useful tool for diagnostics and treatment planning in Dentistry. Despite it’s increasing applicability in dental practice, CBCT has some disadvantages such as the appearance of artifacts, which stand out as one of the largest diagnostic quality loss factors on this images. These artifacts are discrepancies between the reconstructed visual image and the actual contents of the object, making diagnosis unusable. Furthermore, missing structures may appear within the acquired images. Such structures may occur due to different factors, such as patient movement during scanning, image capture and reconstruction process. To improve image quality, it is necessary to understand the types of artifacts and its consequences for the clinical practice of Dentistry. The aim of this study is to review the literature regarding publications related to artifacts in CBCT. Have been found 20 articles that met the inclusion criteria that were divided according to the areas of dentistry : Endodontics, Prosthodontics, Surgery and Traumatology Buco - Maxillo Facial, implantology and orthodontics. All dental materials generate some intensity artifacts. It can be concluded that the use of CBCT should be cautious, your statement should be cautious and cannot be justified where there is no direct benefit to the patient.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectTomografia computadorizadapt_BR
dc.subjectCone beam computed tomographyen
dc.subjectArtifactsen
dc.subjectDentistryen
dc.titleArtefatos em tomografia computadorizada por feixe cônico associados à presença de materiais odontológicos : uma revisão de literaturapt_BR
dc.title.alternativeArtifacts in computed tomography cone beam associated with the presence of dental materials : a literature reviewen
dc.typeTrabalho de conclusão de graduaçãopt_BR
dc.identifier.nrb000999612pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2016pt_BR
dc.degree.graduationOdontologiapt_BR
dc.degree.levelgraduaçãopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples