Mostrar registro simples

dc.contributor.advisorClarke, Thomas Gabriel Rosauropt_BR
dc.contributor.authorLopes, Marcelo de Freitaspt_BR
dc.date.accessioned2017-05-12T02:24:01Zpt_BR
dc.date.issued2017pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/157814pt_BR
dc.description.abstractEste trabalho buscou avaliar a técnica ultrassônica de Tempo de Voo da Onda Difratada (TOFD - Time-Of-Flight-Diffraction) para o monitoramento de trincas de fadiga nucleadas no interior de tubos de aço Superdúplex. Para isso, foram fabricados corpos de prova do tipo single edge bending SE(B) a partir de um tubo de aço Superdúplex sem costura. Estas amostras foram ensaiadas em fadiga, e o crescimento de trinca foi monitorado com as técnicas de TOFD, de Flexibilidade no Descarregamento (Compliance) – durante os ensaios, foram dadas sobrecargas mecânicas que causaram deformação plástica. As deformações serviram de pontos de referência para analisar o crescimento de trinca. Para aferir a validade os resultados obtidos com o TOFD nos ensaios de fadiga e fazer uma correlação com o monitoramento em campo de defeitos em tubos de aço Superdúplex, foi fabricado um padrão que simulou um tubo com defeito interno conhecido. Este padrão foi inspecionado com o TOFD, empregando os mesmos equipamentos e parâmetros utilizados nos ensaios de fadiga. Foi possível monitorar o crescimento de trinca em fadiga utilizando a técnica de TOFD e houve forte correlação entre os dados obtidos com o TOFD e o Compliance. A inspeção no tubo padrão manteve uma diferença entre a medida real e a obtida com o TOFD proporcional às encontradas durante o monitoramento dos ensaios de fadiga.pt_BR
dc.description.abstractThis study aimed to evaluate the ultrasonic technique Time-Of-Flight-Diffraction (TOFD) in monitoring fatigue nucleated cracks within super duplex steel pipes. In order to do it, single edge bending SE (B) specimens were manufactured using a super duplex steel seamless pipe. These samples were tested in fatigue and crack growth was monitored with two different techniques: TOFD and Flexibility in Unloading (Compliance). During the tests, it was used mechanical overloadings so deformation would be cause on the steel pipes. The deformations caused by that served as reference points to analyze the cracking growth. Thus, to assess the validity of the data obtained with the TOFD in fatigue tests, it was made a pattern that simulated a tube with known internal defect. This pattern was inspected with the TOFD, using the same equipment and parameters used in the fatigue tests. A correlation with the monitoring of defects field super duplex steel pipes was also made. The experiment has shown it is possible to monitor the cracking growth fatigue using the TOFD technique. Figures indicate, as well, there is a strong correlation between results obtained with the TOFD and Compliance. The inspection of the standard steel pipe maintained a difference between the actual measurement and obtained measurement. That difference was proportional from TOFD data and those found during the monitoring of the fatigue tests.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectSuper duplexen
dc.subjectTubos de açopt_BR
dc.subjectTOFDen
dc.subjectEnsaios de fadigapt_BR
dc.subjectFlexibility in unloadingen
dc.subjectFatigueen
dc.titleEstudo da utilização da técnica ultrassônica de TOFD com vistas no monitoramento de trincas de fadiga em tubos de aço superdúplexpt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb001020799pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia de Minas, Metalúrgica e de Materiaispt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2017pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples