Mostrar registro simples

dc.contributor.advisorDias, Regina Davisonpt_BR
dc.contributor.authorSotelo, Ruben Rafaelpt_BR
dc.date.accessioned2007-06-06T17:17:52Zpt_BR
dc.date.issued1994pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/1755pt_BR
dc.description.abstractAs fundações empregadas para linhas de transmissão de alta tensão em depósitos de argilas moles saturadas são geralmente estacas. No Rio Grande do Sul, projetos alternativos com fundações superficiais foram empregados em forma experimental para torres de suspensão, as quais apresentaram bom desempenho com menor custo. Esta pesquisa visa apontar critérios racionais da mecânica dos solos que permitam projetar, a partir do conhecimento do perfil de resistência não drenada, fundações superficiais em depósitos de argilas moles saturadas com maior confiabilidade. Para a determinaçao do perfil de resistência não drenada foi desenvolvido um cone manual com leituras elétricas, o qual foi testado apresentando bons resultados. A vantagem do uso deste equipamento reside no fato de que pode ser transportado manualmente a locais de difícil acesso, onde são implantadas as torres de alta tensão. Os demais parâmetros de solos do local de estudo, situado no município de Canoas no Rio Grande do Sul, foram obtidos a partir de ensaios de compressão triaxial do tipo adensado isotropicamente não drenado (CIU) com medida de poro pressão e de ensaios de adensamento. Foram analisadas as fundações superficiais das torres de suspensão projetadas, empregando teorias analíticas convencionais, baseadas no conhecimento da resistência não drenada, e o método de elementos finitos. A partir deste estudo, é sugerida uma metodologia para projetos de fundações superficiais de torres de suspensão em argilas moles saturadas.pt_BR
dc.description.abstractPiles are generally used as foundations of power transmission lines in saturated soft clays. Shallow foundations for suspension towers have been experimentally used as an alternative in Rio Grande do Sul State. Satisfactory results at lower costs were achieved. This research attempts to indicate, knowing the undrained shear strength profile, rational soil mechanics criteria for more reliable design of footings in saturated soft clays. In arder to determinate the undrained shear strength profile, a hand electrical cone was developed. This device was tested with good results and presents the advantage of being easily carried to difficult access sites where the towers are installed. A site located in Canoas (Rio Grande do Sul State) was studied. Besides undrained shear strength other parameters were obtained from triaxial compression tests of the CIU type, with pore pressure measurement, and also consolidation tests. Shallow foundations of suspension towers were analyzed using tradtional analytical theories, based in undrained shear strength, and the finite element method. As a result of the research a method is suggested for the design of shallow foundations suspension tower on saturated soft clays.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectFundações superficiais (Engenharia)pt_BR
dc.subjectLinhas de transmissãopt_BR
dc.subjectMecânica dos solospt_BR
dc.titleFundações superficiais para linhas de transmissão em argilas moles saturadaspt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb000262237pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.programCurso de Pós-Graduação em Engenharia Civilpt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date1994pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples