dc.description.abstractOBJETIVO Avaliar a correlação e concordância entre medidas ecocardiográficas das dimensões cardíacas, obtidas através do aplicativo Echo off-line (programa para obtenção de medidas de imagens digitalizadas em estação de trabalho dedicada), com as realizadas convencionalmente. MÉTODOS Estudo transversal, contemporâneo, sendo randomizados 56 pacientes. Através do programa Echo off-line foram mensuradas as medidas ao modo M e 2D ao nível dos ventrículos, do átrio esquerdo e da aorta. Estas medidas foram comparadas às realizadas por outro profi ssional, através do teste de correlação de Pearson (r), com alfa crítico de 0,05 e pela análise de concordância (Bland e Altman). RESULTADOS As mensurações realizadas no sistema Echo offline demonstraram r de 0,85 a 0,98. A análise de concordância mostrou que, para a maioria das medidas, a diferença média entre os métodos foi aproximadamente zero. A variação de valores absolutos não apresentou, em média, signifi cância clínica. O aplicativo Echo off-line permite uma redução de, aproximadamente, 30% no tempo para realização das medidas. CONCLUSÃO Este trabalho demonstrou a acurácia do programa Echo off-line para mensurar as dimensões cardíacas em estação de trabalho dedicada, podendo ser utilizado rotineiramente nos laboratórios de ecocardiografia.pt_BR
dc.description.abstractOBJECTIVE To evaluate the correlation and concordance between the measurements of echocardiographic analysis of cardiac dimensions obtained through the Echo off-line applicative (software for obtaining digitized image measurements in a dedicated workstation) available to public domain, and those obtained through the conventional method. METHOD Transversal contemporary study, of 56 randomized patients whose images were obtained during examinations. The measurements of the M mode and 2D, were done in the ventricles, left atrium, and aorta by the Echo off-line program. These measurements were compared to those obtained by another professional, through Pearson’s correlation test (r), alpha = 0.05 and by concordance analysis (Bland and Altman). RESULT The measurements carried out by the Echo off-line system showed r that varied from 0.85 to 0.98. The analysis of concordance showed that for most measurements, the mean difference between the methods was approximately zero. The variation of absolute values did not show, in average, a clinical signifi cance. The Echo off-line applicative allows a reduction of approximately 30% in the time spent to obtain the measurements. CONCLUSION This study demonstrated the accuracy of the Echo off-line program to measure cardiac dimensions in a dedicated workstation, showing that it can be routinely used in echocardiography labs.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofArquivos brasileiros de cardiologia. [São Paulo, SP]. vol. 86, n. 4 (abr. 2006), p. 283-288pt_BR
dc.rightsOpen Accessen
dc.subjectInterpretation of image guided by computeren
dc.subjectProcessamento digital de imagenspt_BR
dc.subjectEcocardiografiapt_BR
dc.subjectEchocardiographyen
dc.subjectPublic domain programen
dc.titleCorrelação e concordância entre medidas ecocardiográficas obtidas durante o exame no ecocardiógrafo com medidas de imagens digitalizadas : estudo transversalpt_BR
dc.title.alternativeCorrelation and concordance between echocardiographic measurements obtained during echocardiography and digitized image measurements: transversal studyen
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000531390pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples