Mostrar registro simples

dc.contributor.authorFurlanetto, Tássia Silveirapt_BR
dc.contributor.authorSedrez, Juliana Adamipt_BR
dc.contributor.authorCandotti, Cláudia Tarragôpt_BR
dc.contributor.authorDutra, Vinícius Hoffmannpt_BR
dc.contributor.authorVieira, Adrianept_BR
dc.contributor.authorLoss, Jefferson Fagundespt_BR
dc.date.accessioned2021-05-13T04:24:57Zpt_BR
dc.date.issued2020pt_BR
dc.identifier.issn0161-4754pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/220756pt_BR
dc.description.abstractTo analyze the concurrent validity of the Digital Image-based Postural Assessment (DIPA) method for identifying the magnitude and classification of thoracic kyphosis in adults. Methodology On the same day and in the same place, thoracic kyphosis was assessed in 68 adults using 2 methods: the DIPA software protocol and radiography. The DIPA software provided angular values of thoracic kyphosis based on trigonometric relations, while with the radiograph, the curvature was calculated using the Cobb method. The following tests were applied in the statistical analysis: Pearson's correlation, Bland-Altman's graphic representation, root mean square error, and receiver operating characteristic (ROC) curve; α = 0.05. The reference angular values for the standard thoracic posture used in DIPA were determined with the ROC curve based on the Cobb angles. Results The correlation between the angles obtained for thoracic kyphosis using the DIPA and Cobb methods was found to be high (r = 0.813, P < .001), and the accuracy was ±4°. According to Bland-Altman's representation, the magnitudes provided by the DIPA software were in agreement with those of the Cobb method. In reference values for determining the standard posture of the thoracic spine, the ROC curve indicated good accuracy in diagnosing a decrease in thoracic kyphosis (with a value of 33.9°) and excellent accuracy in diagnosing thoracic hyperkyphosis (with a value 39.9°) when using DIPA. Conclusion The DIPA postural assessment method is valid in the sagittal plane for identifying the magnitude of thoracic kyphosis in adults. Furthermore, it is accurate in diagnosing alterations in thoracic kyphosis.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoengpt_BR
dc.relation.ispartofJournal of Manipulative and Physiological Therapeutics. Lombard. Vol. 43, n.2 (Feb. 2020), p. 93-99pt_BR
dc.rightsOpen Accessen
dc.subjectKyphosisen
dc.subjectFotogrametriapt_BR
dc.subjectValidity of Resultsen
dc.subjectCifosept_BR
dc.subjectPostura corporalpt_BR
dc.subjectPhotogrammetryen
dc.subjectEstudos de validaçãopt_BR
dc.titleConcurrent validity of digital image-based postural assessment as a method for measuring thoracic kyphosis : a cross-sectional study of healthy adultspt_BR
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb001125404pt_BR
dc.type.originEstrangeiropt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples