Mostrar registro simples

dc.contributor.advisorPereira, Adamastor Humbertopt_BR
dc.contributor.authorDutra, Clandio de Freitaspt_BR
dc.date.accessioned2007-06-06T17:21:01Zpt_BR
dc.date.issued2001pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/2249pt_BR
dc.description.abstractOs stents são dispositivos intravasculares implantados com o objetivo de dilatar ou fixar a placa de colesterol contra a parede arterial. O objetivo avaliar dois tipos de stents de aço inoxidável, um recoberto com poliéster (dacron) e outro não recoberto, implantados na aorta infra-renal de suínos jovens, foram avaliados por morfometria digital para medir o espessamento intimal. Foi realizado um estudo experimental randomizado, separados em dois grupos(stents não revestidos e revestidos com dacron) e duas fases (I e II). Oito stents recobertos com dacron e oito stents de aço inoxidável (30mm de extensão e 8 mm de diâmetro), não revestidos, foram implantados através de abordagem retroperitoneal na aorta infrarenal normal de 16 suínos normolipêmicos. Para a passagem do sistema de implante, foi necessário uma pequena arteriotomia na aorta distal (fase I). Após quatro semanas, a aorta com os stents foram removidas em monoblocos (fase II). Os valores de hematimetria e do lipidograma foram coletados nas duas fases e não apresentaram alterações que pudessem influenciar o estudo. Amostras de tecido dos sítios de fixação (proximal e distal) dos stents foram retiradas, confeccionadas lâminas, que foram coradas pelas técnicas de hematoxilina e eosina de Verhoeff e enviadas para análise morfométrica digital. A camada intima distal não apresentou diferença estatística significativa. A camada média proximal das porções proximal e da porção distal não apresentaram diferença entre os grupos. Os dois tipos de stents apresentaram 100% de perviedade, boa biocompatibilidade e boa incorporação a parede aórtica de suínos normolipêmicos. A camada íntima proximal do grupo de stents revestidos com dacron apresentou espessura maior do que os stents não revestidos, mas com significância estatísitica limítrofe.pt_BR
dc.description.abstractStents are intravascular devices implanted with the objective of dilating or fixing the cholesterol plate against the arterial wall. To evaluate, by digital morphometry, the intimal thickening after the placement of two different kinds of stents: polyester covered stainless steel stents (Dacron) and non-covered stents implanted in young pigs’ infrarenal aortas. The stents were made at the Biotransformation Laboratory of Federal University of Rio Grande do Sul. The experiment was performed at the Biotério of University of Caxias do Sul, carried out on two separate groups of pigs. Eight polyester-covered stainless steel stents (Dacron) and eight stainless steel stents (30-mm long, 8-mm diameter) were deployed through extraperitoneal approach in the normal infrarenal aorta of 16 normolipemic pigs. To allow the passage of the delivery system, a small arteriotomy was performed (phase I). After four weeks, the aorta with the stent was removed en bloc. (phase II). The values of the hematimetric and lipid analysis did not show any changes that could influence the study. Tissue samples of the fixing sites (proximal and distal) of the stents were taken. Microscope slices were prepared and submitted to Verhoeff’s hematoxilin and eosin techniques and sent to morphometric analysis.The intima immediately proximal to the device was thicker in the group of covered stents with marginal significance. The distal intimal layer, proximal medial layer of the proximal portion and distal portion did not present statistical difference between the two groups. Patency was 100% in both groups of these normolipemic pigs. After four weeks the intimal layer immediately proximal to the covered stents was ticker when compared to uncovered stents, but this had a borderline significance. The intimal layer distal to covered stents and the media proximal or distal to the devices had similar morphometric features when covered and uncovered stents where compared.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectCirurgiapt_BR
dc.subjectIntimal thicknessen
dc.subjectModelos animaispt_BR
dc.subjectStainless steel stentsen
dc.subjectAortapt_BR
dc.subjectDacronen
dc.subjectMorphometric analysisen
dc.subjectStentspt_BR
dc.subjectEstudo comparativopt_BR
dc.subjectSuínospt_BR
dc.titleAnálise morfométrica digital na parede aórtica de suínos após implante de stents não revestidos versus stents revestidos com dacronpt_BR
dc.title.alternativeDigital morphometric analysis on the aortic wall of pigs after implants of non coated stents versus coated stents with dacron en
dc.typeDissertaçãopt_BR
dc.identifier.nrb000366548pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Medicinapt_BR
dc.degree.programPrograma de Pós-Graduação em Medicina: Cirurgia (até ago. 2008)pt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2001pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples