dc.description.abstractOs processos de galvanoplastia muitas vezes possuem componentes com altos potenciais toxicológicos provenientes da composição e das reações ocorridas nos banhos. Para se realizar um controle deste ambiente de trabalho uma das medidas a ser tomada é o projeto de um sistema de ventilação local exaustora. Este consiste em captar os poluentes junto ao ponto de geração, transportá-los por um sistema de dutos através de um ventilador centrifugo e realizar a purificação do ar por um lavador de gases. Este trabalho tem como objetivo dimensionar um sistema de dutos para realizar a exaustão dos poluentes dos tanques de remoção de cromo e remoção de cádmio de um setor de galvanoplastia de uma empresa de manutenção aeronáutica. Para isso se dimensionou um sistema de dutos com duas ramificações e um duto principal. Esse dimensionamento foi realizado pelo balanceamento do sistema através da obtenção da mesma perda de carga em cada ramificação. O duto principal do sistema foi projetado de forma a se adequar ao layout da instalação, visando uma menor perda de carga para o sistema. Além disso, os outros componentes do sistema de ventilação local exaustora também foram selecionados. Para o ventilador do sistema foram escolhidos dois modelos de diferentes fabricantes mais adequados para o processo. Para se complementar o projeto também foi escolhido um lavador de gases tipo torre de enchimento para realizar a purificação do ar proveniente do processo.pt_BR
dc.description.abstractOperations performed in electroplating often have components with high potential that can be produced from the reactions in the baths. To make the control of the workplace, one of the measures to be taken is the design of a system of local exhaust ventilation. This is to capture the pollutants close to the point of generation, transport them to a duct system, and perform the purification of air through a gas washer. The main objective of this paper is to design a duct system to a of local exhaust ventilation system to pollutants generated in the tanks of chromium removal and cadmium removal, in a electroplating of a company aircraft maintenance. For this, one designed a duct system with two branches and a main duct. This scaling was done by balancing the system by obtaining the same pressure drop in each branch. The main duct system was designed to fit the layout of the facility, aiming at a lower pressure drop for the system. In addition, other components of the local exhaust ventilation were also selected. For the fan system we have chosen two models of different manufacturers most suitable for the process. To complement the project, it was also chosen an air washes to perform the purification of air from the process.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectLocal exhaust ventilationen
dc.subjectEngenharia mecânicapt_BR
dc.subjectDuct systemen
dc.subjectHoodsen
dc.subjectElectroplatingen
dc.titleDimensionamento de um sistema de dutos para um sistema de ventilação local exaustora em galvanoplastiapt_BR
dc.title.alternativeDesign of duct system to local exhaust ventilation in a electroplating en
dc.typeTrabalho de conclusão de graduaçãopt_BR
dc.identifier.nrb000742663pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2009pt_BR
dc.degree.graduationEngenharia Mecânicapt_BR
dc.degree.levelgraduaçãopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples