Mostrar registro simples

dc.contributor.authorSouza, Catianept_BR
dc.contributor.authorCardoso, Nicholas Kostopoulospt_BR
dc.contributor.authorWagner Neto, Edgar Santiagopt_BR
dc.contributor.authorGertz, Luiz Carlospt_BR
dc.contributor.authorLoss, Jefferson Fagundespt_BR
dc.date.accessioned2022-07-13T04:54:04Zpt_BR
dc.date.issued2020pt_BR
dc.identifier.issn0103-1716pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/242350pt_BR
dc.description.abstractFrente à necessidade de avaliações rápidas e com baixo custo da força de flexores do tronco, o objetivo do presente estudo foi desenvolver um dinamômetro para avaliar a força de flexores do t ronco. Foi desenvolvido um protótipo para avaliar a força de flexão do tronco a partir da posição sentada. Foram avaliadas a validade do instrumento, comparando os valores medidos com cargas previamente conhecidas, a repetibilidade (avaliações consecutivas) a reprodutibilidade no tempo (avaliações com um dia de intervalo) e a reprodutibilidade de posição (com a carga sendo aplicada em diferentes pontos do instrumento). Foi testada a normalidade dos dados com o teste de Shapiro-Wilk. A validade das m edidas foi analisada com base no teste-t e no erro RMS (raiz quadrada das médias quadráticas). A repetibilidade e a reprodutibilidade foram avaliadas pelo teste-t, pelo erro RMS entre as medidas e pelo ICC (coeficiente de correlação intraclasse). Na reprodutibilidade intra-posição utilizou-se t ambém um a ANOVA. Não foram encontradas diferenças entre as situações avaliadas. Em todos os testes, o ICC foi classificado como excelente (>0.995) e foram encontrados baixos valores de erro RMS (erro padrão de medida) (<1,5 k gf), SEM (mínima mudança detectável) (<1,3 kgf) e MDC (<2,3 kgf). Frente aos resultados obtidos, conclui - se que o instrumento desenvolvido apresenta validade, repetibilidade e reprodutibilidade no tempo e posição.pt_BR
dc.description.abstractConsidering the need for rapid and low-cost assessments of trunk flexor strength, the objective of the present study was to develop a dynamometer that is able to assess the stren gth o f t run k flexors. A prototype was developed to evaluate trunk flexion from the sitting position. The validity of th e instrument was evaluated by comparing the measured values with previously known loads, repeatability (consecutive evaluations), time reproducibility (one-day interval evaluations) and position-reproducibilit y (with the load being applied at different points of the instrument). The normality of the data was t est ed with the Shapiro-Wilk test. The validity of the measures was analysed based on the t -test an d t he roo t mean square (RMS) error. Repeatability and reproducibility were evaluated by t-test, RMS error between measurements; and Intraclass correlation coefficient (ICC). An ANOVA was also used for intra-position reproducibility. No differences were found between the evaluated situations. In all tests the ICC was classified as excellent (> 0.995) as well as low values of RMS error (<1.5 kgf), standard error of measurement (SEM) (<1.3 kgf) and minimal detectable change (MDC) (<2.3 kgf). With the results obtained it is concluded that the developed instrument presents validity, repeatability and time and position reproducibility.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofRevista Brasileira de Ciência e Movimento. Distrito Federal, Universidade Católica de Brasília/Universidade Federal de Mato Grosso do Sul , 2018. Vol. 28, no.1 (2020), p. 116-126.pt_BR
dc.rightsOpen Accessen
dc.subjectCoreen
dc.subjectForça muscularpt_BR
dc.subjectMuscle strengthen
dc.subjectBiomecânicapt_BR
dc.subjectBiomechanicsen
dc.subjectTrunk flexorsen
dc.titleDesenvolvimento de um dinamômetro para medir força de flexão do troncopt_BR
dc.title.alternativeDevelopment of a dynamometer for measuring trunk flex force en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb001142572pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples