Mostrar registro simples

dc.contributor.authorConceição, Andréa de Azevedo Britopt_BR
dc.contributor.authorConceição, Ewerton Nocchipt_BR
dc.contributor.authorDantas, Darlenept_BR
dc.contributor.authorRhost, Déborapt_BR
dc.contributor.authorBiehl, Adriana Carbonipt_BR
dc.date.accessioned2010-08-05T04:18:12Zpt_BR
dc.date.issued2008pt_BR
dc.identifier.issn0566-1854pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/24942pt_BR
dc.description.abstractO presente estudo avaliou três diferentes marcas comerciais de compósitos quanto à fenda resultante da contração de polimerização: Esthet-X (Dentsply); Filtek Z350 (3MESPE); Concept (Vigodent) todos na cor A3. Os compósitos foram inseridos numa matriz metálica com 7mm de diâmetro interno e 2mm de altura, sendo prensados entre 2 placas de vidro e fotopolimerizados por 40 segundos em uma das superfícies com aparelho de luz halógena XL 3000 (3M/ESPE) a 500 +/- 10 mW/cm2. Após foram polidos em politriz, metali zados em ouro e levados para análise da fenda resultante da contra ção de polimerização em um microscópio eletrônico de varredura (Philips XL30). Foram feitas 4 medições para cada corpo de prova em áreas correspon dentes a 3, 6, 9 e 12 horas. Os resultados foram submetidos à análise de variância ANOVA e teste de Tukey, ao nível de signifi cância de 5%. Os resultados mostraram os seguintes valores médios para as fendas de contração dos compósitos: Consept (35,77 μm); Esthet-X (22,01μm); Filtek Z350 (17,95μm), o que demonstrou que o grupo Con diferiu estatisticamente dos demais apresentado maior valor médio em relação à fenda de contração. Baseados nos resultados obtidos, foi possível concluir que o compósito Concept apresentou maior contração de polimerização quando compa rado às Resinas Compostas Esthet-X e Filtek Z350.pt_BR
dc.description.abstractThis study evaluated three different brands of composite resins on the slot resulting from the polymerization contraction: Esthet X (Dentsply); Filtek Z350 (3M / ESPE); Concept (Vigodent), all of them in color A3. Composites were placed in a metal matrix with 7mm in internal diameter and 2mm in height, being pressed between 2 glass plaques and photopolymerized for 40 seconds in one of the surfaces with a polymerization system by halogen light XL 3000 (3M/ ESPE) to 500 +/- 10 mW/cm2. After that, it was polished in politriz, metallized in gold and taken for analysis of the slot resultant of the polymerization contraction in a scanning electron microscope (SEM, Philips XL30). Four measurements were made for each body of evidence in areas corresponding to 3, 6, 9 and 12 hours The results were submitted to one-way ANOVA and Tukey’s test, at the signifi - cance level of 5%. The results showed the following average values for the contraction slots of composites: Concept (35.77 μm); Esthet X (22.01 μm); Filtek Z350 (17.95 μm). It demonstrates that Con group was statistically different from the others presenting a bigger average contraction gap. Based on the results it was possible to conclude that Concept composite presented the biggest polimerization contraction when compared with Esthet-X and Filtek Z350.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.relation.ispartofRevista da Faculdade de Odontologia de Porto Alegre. Porto Alegre. Vol. 49, n. 1 (jan./abr. 2008), p. 31-33pt_BR
dc.rightsOpen Accessen
dc.subjectResinas compostaspt_BR
dc.subjectComposite resinsen
dc.subjectDental stress analysisen
dc.subjectMateriais odontologicos : Propriedades fisicaspt_BR
dc.subjectPhysical and chemical propertiesen
dc.titleMensuração da contração de polimerização de resinas compostas através da microscopia eletrônica de varredurapt_BR
dc.title.alternativeMensuration of the polimerization shrinkage of composites through scanning electron microscope en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000750039pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples