Mostrar registro simples

dc.contributor.advisorSchaeffer, Liriopt_BR
dc.contributor.authorVillarinho, Denis Jardimpt_BR
dc.date.accessioned2010-08-11T04:18:24Zpt_BR
dc.date.issued2010pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/25054pt_BR
dc.description.abstractNo presente trabalho foi feito estudo em ligas metálicas comerciais de NiTi , chapa atuador tipo M com 0,5 mm de espessura e liga 3M termoativada , fio com 0,48mm X 0,64mm referência 4297-919, com secção transversal retangular, afim de caracterizar material a ser utilizado no ciclo operacional de fabricação do grampo de Judet. . Para a caracterização do fio e da chapa foi decidido se usar inicialmente o DSC (Differential Scanning Calorimeter) Calorímetro Diferencial de Varredura. Esses testes foram realizados com o intuito de se determinar as temperaturas de transformação de fases das ligas. Com esse teste foi observado, que a liga M não era a melhor escolha para ser utilizada como grampo de Judet, devido às temperaturas mostradas, Mf , Ms, As e Af por serem apropriadas para atuadores. A liga 3M com características de liga tipo BT, Body temperature, temperatura corporal, mostrou-se adequada ao grampo em estudo. Mesmo assim foi decidido caracterizar e fabricar o grampo com a liga tipo M pela disponibilidade. Com a liga 3M seria preciso para resfriar a peça, somente soro fisiológico esterilizado a 4ºC para a completa transformação martensítica, também significava que esta peça teria total transformação austenítica a 37ºC, temperatura do corpo humano, quando incluída. Depois disso a chapa tipo M, e o fio 3M, foram observadas com o teste BFR (Bend and Free Recovery) Curvatura e Livre Recuperação, que mostra sua recuperação depois de deformada, em relação a variação de temperatura, teste recomendado para caracterizar ligas níquel-titânio com Af= -25ºC até 90ºC . Suas secções transversais foram observadas ao microscópio óptico. Ensaios de tração foram realizados nas duas ligas. Das curvas obtidas nos testes, foi calculado o módulo de elasticidade e observada a resiliência. Depois de vários experimentos com diversas amostras, observando-se a memória de forma e a superelasticidade foi estabelecido o ciclo operacional de fabricação: a) Corte da chapa na guilhotina; b) Estampar o grampo de Judet na prensa; c) Tratamento térmico no forno Sanchis; d) Tamboreamento para retirar rebarbas na Roto Finish; e) Lavagem Intermediária; f) Eletro-polimento; g) Lavagem ultrassônica; h) Embalagem em seladora cirúrgica e i) Esterilização em autoclave.pt_BR
dc.description.abstractIn this work a study was made on commercial alloys of NiTi, actuator sheet type M with 0.5 mm thick and 3M heat activated, wire with 0.48 mm X 0.64 mm reference 4297-919 with rectangular cross-section, order to characterize the material to be used in the manufacturing cycle time staple Judet. . In characterizing the wire and the sheet was initially decided to use the DSC (Differential Scanning Calorimeter). These tests were conducted to determine the phase transformation temperatures of alloys. With this test, it was observed that the alloy M was not the best choice for use as a staple of Judet, due to the temperatures shown, Mf, Ms, As, Af, suitable for actuators. The alloy features with 3M alloy type BT (Body temperature) was adequate to staple study. Even so it was decided to characterize and produce the staple with type M for availability. With the alloy 3M would have to cool the part, only with sterile saline at 4 º C for complete martensitic transformation also meant that the part would have total austenitic transformation at 37 ° C, when inserted. After that the sheet type M, and the wire 3M, were observed with the test BFR (Bend and Free Recovery) which shows his deformed recovery in relation to temperature change, recommended test to characterize nickel-titanium alloy with Af = -25 º C to 90 º C. Also their cross sections were observed under an optical microscope. Tensile tests were carried out in two alloys. On the curves obtained in the tests, were calculated the modulus of elasticity and resilience observed. After many experiments with different samples, observing the shape memory and super-elasticity was established cycle time of manufacture: a) Cut the plate in the guillotine; b) Stamping Judet staple in press; c) Heat treatment in oven Sanchis; d) Tumbling to remove burrs in the Roto Finish; e) Washing Intermediate; f) Electro-polishing; g) Washing Ultrasonic; h) Packaging sealing operation; i) Sterilization by autoclaving.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectLigas de níquel-titâniopt_BR
dc.subjectBiomateriaispt_BR
dc.titleCaracterização de uma liga NiTi visando confecção e aplicação como material biomédico em órtese Grampo de Judetpt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb000750001pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia Minas, Metalúrgica e de Materiaispt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2010pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples