Mostrar registro simples

dc.contributor.authorGomes, Cristianopt_BR
dc.contributor.authorGouvea, Aline Silvapt_BR
dc.contributor.authorAlievi, Marcelo Mellerpt_BR
dc.contributor.authorContesini, Emerson Antôniopt_BR
dc.contributor.authorPippi, Ney Luispt_BR
dc.date.accessioned2011-03-26T06:01:50Zpt_BR
dc.date.issued2009pt_BR
dc.identifier.issn0103-8478pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/28291pt_BR
dc.description.abstractFraturas de mandíbula e maxila são comuns em cães e gatos, correspondendo a cerca de 3 a 6% de todas as fraturas. Muitos tratamentos são propostos para a correção desse defeito, como o uso de pino intramedular, a fixação esquelética externa, a cerclagem e o uso de acrílicos e placas ósseas. Este estudo teve como objetivo avaliar o uso das mini e microplacas de titânio do sistema 2,0 e 1,5mm no tratamento de fraturas mandibulares, em cães e gatos, respectivamente. Os parafusos e as miniplacas utilizadas são compostos de titânio, e o formato dependeu da localização e do tipo de fratura. No total, foram avaliados seis casos, dos quais quatro apresentaram completa consolidação, sendo as placas utilizadas como método único ou associado com fio de aço ou imobilização com focinheira. As causas de insucesso foram a quebra da placa em um dos casos e a contaminação do enxerto, com posterior osteomielite em decorrência da deiscência dos pontos em outro caso. O emprego das miniplacas de titânio mostrou-se eficaz na maioria dos casos testados, promovendo fixação rígida e retorno funcional adequado, sendo utilizado como método único ou associado com outras técnicas de osteossíntese.pt_BR
dc.description.abstractJaw and maxilla fractures are common in dogs and cats, representing 3-6% of all fractures. Numerous techniques are proposed to reduce the defect such as intramedullary pin, percutaneous skeletal fixation, circumferential wiring, acrylic splints and bone plating. This study aimed to evaluate the use of 2.0mm and 1.5mm titanium microplates in the treatment of mandibular fractures in dogs and cats, respectively. The screws and the mini and microplates used were composed of titanium and their format depended on the location and type of fracture. A total of 6 cases were selected and 4 of them had complete consolidation using the mini microplate method alone or associated with steel wire or tie with noseband. In one case the failure occurred due to plate breakage and other implant failed due to dehiscence of the skin suture. The use of mini titanium microplates was effective in most cases, as a single method or combined with other techniques of osteosynthesis, because it promoted rigid fixation and return to the appropriate function..en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoengpt_BR
dc.relation.ispartofCiencia rural. Santa Maria. Vol. 40, n. 5 (maio. 2010), p. 1128-1133pt_BR
dc.rightsOpen Accessen
dc.subjectDogen
dc.subjectCirurgia veterinariapt_BR
dc.subjectCaten
dc.subjectFraturas maxilomandibularespt_BR
dc.subjectSurgeryen
dc.subjectOsteosynthesisen
dc.subjectJawen
dc.subjectBuco maxillofacialen
dc.titleMiniplacas de titânio na redução de fraturas mandibulares em cães e gatos: estudo de seis casospt_BR
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000747700pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples