Mostrar registro simples

dc.contributor.authorFragoso, Yára Dadaltipt_BR
dc.contributor.authorNosé, Ricardo Menonpt_BR
dc.contributor.authorNosé, Regina Aidar Menonpt_BR
dc.contributor.authorNosé, Waltonpt_BR
dc.contributor.authorVieira, Simonept_BR
dc.contributor.authorFinkelsztejn, Alessandropt_BR
dc.date.accessioned2012-03-02T01:20:09Zpt_BR
dc.date.issued2011pt_BR
dc.identifier.issn0004-282Xpt_BR
dc.identifier.urihttp://hdl.handle.net/10183/37292pt_BR
dc.description.abstractObjetivo: Avaliar a qualidade de vida visual de pacientes com esclerose múltipla (EM) e observar se este parâmetro pode ser relacionado aos achados do exame oftalmológico. Método: O questionário traduzido e validado 25-Item National Eye Institute Visual Function Questionnaire (VFQ-25) foi utilizado para avaliar a qualidade de vida visual. Dados clínicos da EM, acuidade visual, campo visual, tomografia de coerência óptica (OCT) e escavação do disco foram utilizados para correlação com VFQ-25. Resultados: A média do VFQ-25 foi 78,6±18,2% em 27 pacientes. VFQ-25 não se correlacionou com a idade dos pacientes, com a incapacidade (EDSS), duração da doença ou medicação em uso. A acuidade visual mostrou uma correlação relativamente pobre (<60%) com VFQ-25, enquanto não foi observada nenhuma correlação entre campo visual, OCT e escavação de disco com VFQ-25. Conclusão: Pacientes com EM apresentam diversas alterações oculares e na visão que não podem ser avaliadas por medidas isoladas. O exame oftalmológico destes pacientes deve incluir parâmetros que não são habitualmente utilizados em consultas oftalmológicas padronizadas.pt_BR
dc.description.abstractObjective: To assess the visual quality of life in patients with multiple sclerosis (MS), and to observe whether this parameter could be correlated to the findings of the ophthalmologic examination. Method: The translated and validated 25-Item National Eye Institute Visual Function Questionnaire (VFQ-25) was used to assess the visual quality of life. Clinical data on MS, visual acuity, visual fields, optic coherence tomography (OCT) and disc cupping were used for assessing correlation with VFQ-25. Results: The mean VFQ-25 value was 78.6±18.2% in 27 patients. VFQ-25 did not correlate with patients’ ages, with disability (EDSS), disease duration or medication use. Visual acuity showed a relatively poor (<60%) correlation to VFQ-25, while no correlation could be established between visual fields, OCT and disc cupping with VFQ-25. Conclusion: MS patients present several alterations in their eyes and sight that cannot be assessed by isolated measures. Ophthalmological examination of these patients must include many parameters not usually used in standard ophthalmologic consultations.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoengpt_BR
dc.relation.ispartofArquivos de neuro-psiquiatria. Vol. 69, n. 5 (2011), p. 809-813pt_BR
dc.rightsOpen Accessen
dc.subjectEsclerose múltiplapt_BR
dc.subjectMultiple sclerosisen
dc.subjectOftalmologiapt_BR
dc.subjectOphthalmologyen
dc.subjectvisual acuityen
dc.subjectAcuidade visualpt_BR
dc.subjectVisual fieldsen
dc.subjectTomografia de coerência ópticapt_BR
dc.subjectQualidade de vidapt_BR
dc.subjectOptic coherence tomographyen
dc.subjectQuality of lifeen
dc.titleSight-dependent quality of life and ophthalmic findings in a group of Brazilian patients with multiple sclerosispt_BR
dc.title.alternativeQualidade de vida visual e achados oftálmicos em um grupo de pacientes brasileiros com esclerose múltipla pt
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000816446pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples