Mostrar registro simples

dc.contributor.authorZanella, André Borsattopt_BR
dc.contributor.authorMeyer, Erika Laurini de Souzapt_BR
dc.contributor.authorBalzan, Leticia Maffazzioli Santospt_BR
dc.contributor.authorSilva, Antonio Carlos dapt_BR
dc.contributor.authorCamargo, Joiza Linspt_BR
dc.contributor.authorMigliavaca, Alceupt_BR
dc.contributor.authorGuimaraes, Jose Ricardopt_BR
dc.contributor.authorMaia, Ana Luiza Silvapt_BR
dc.date.accessioned2012-05-03T01:26:40Zpt_BR
dc.date.issued2010pt_BR
dc.identifier.issn0004-2730pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/40093pt_BR
dc.description.abstractObjetivo: O objetivo deste estudo foi avaliar a acurácia da dosagem de tireoglobulina no lavado da agulha da punção aspirativa (PAAF-Tg) de linfonodos (LN) cervicais para detecção de metástases do câncer papilar de tireoide (CPT). Sujeitos e métodos: Foram incluídos 43 pacientes (51,4 ± 14,6 anos) com diagnóstico de CPT e evidência de LN cervicais aumentados. Os LN suspeitos foram submetidos à punção aspiração com agulha fina guiada por ecografia para análise citológica e dosagem de tireoglobulina (PAAF-Tg). Resultados: A mediana dos valores de PAAF-Tg nos LN metastáticos (n = 5) foi 3.419,0 ng/mL (11,1-25.538), enquanto nos LN não metastáticos (n= 38) a mediana foi de 3,7 ng/mL (0,8-7,4). Utilizando-se o nível de 10 ng/mL como ponto de corte, observaram-se sensibilidade e especificidade de 100%. Os níveis de TSH sérico não interferiram na dosagem de PAAF-Tg (3,3 e 3,8 ng/mL nos grupos com TSH supresso (TSH 0,07 mUI/mL) e hipotireoidismo (TSH 97,4 mUI/mL), respectivamente, P = 0,2). Conclusão: Os resultados demonstram que a dosagem de PAAF-Tg é uma ferramenta importante no diagnóstico de metástases do CPT, podendo ser utilizada independente do “status” tireoidiano.pt_BR
dc.description.abstractObjective: The aim of this study was to evaluate the accuracy of the measurement of thyroglobulin in washout needle aspiration biopsy (FNAB-Tg) to detect papillary thyroid cancer (PTC) metastases. Subjects and methods: Forty-three patients (51.4 ± 14.6 years) with PTC diagnosis and evidence of enlarged cervical lymph nodes (LN) were included. An ultrasound-guided fine-needle aspiration of suspicious LN was performed, for both cytological examination and measurement of FNAB-Tg. Results: The median values of FNAB-Tg in patients with metastatic LN (n = 5) was 3,419 ng/mL (11.1-25,538), while patients without LN metastasis (n = 38) showed levels of 3.7 ng/mL (0.8-7.4). Considering a 10 ng/mL cutoff value for FNAB-Tg, the sensitivity and specificity was 100%. There were no differences on the median of FNAB-Tg measurements between those on (TSH 0.07 mUI/mL) or off levothyroxine (TSH 97.4 mUI/mL) therapy (3.3 vs. 3.8 ng/mL, respectively; P = 0.2). Conclusion: The results show that evaluation of FNAB-Tg in cervical LN is a valuable diagnostic tool for PTC metastases that can be used independent of the thyroid status.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofArquivos brasileiros de endocrinologia & metabologia. Vol. 54, n. 6 (ago. 2010), p. 550-554pt_BR
dc.rightsOpen Accessen
dc.subjectMetástase neoplásicapt_BR
dc.subjectPapillary thyroid carcinomaen
dc.subjectMetastases in cervical lymph nodesen
dc.subjectNeoplasias da glândula tireóidept_BR
dc.subjectThyroglobulin;en
dc.subjectBiópsia por agulhapt_BR
dc.subjectLinfonodospt_BR
dc.subjectTSHen
dc.subjectTireoglobulinapt_BR
dc.titleThyroglobulin measurements in washout of fine needle aspirates in cervical lymph nodes for detection of papillary thyroid cancer metastasespt_BR
dc.title.alternativeDeterminação da tireoglobulina no lavado da agulha da punção aspirativa de linfonodos cervicais para detecção de metástases do câncer papilar de tireoide pt
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000763977pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples