Mostrar registro simples

dc.contributor.authorChaise, Fabiana de Oliveirapt_BR
dc.contributor.authorCandotti, Cláudia Tarragôpt_BR
dc.contributor.authorLa Torre, Marcelopt_BR
dc.contributor.authorFurlanetto, Tássia Silveirapt_BR
dc.contributor.authorPelinson, Patricia Paula Toninpt_BR
dc.contributor.authorLoss, Jefferson Fagundespt_BR
dc.date.accessioned2012-12-15T01:36:48Zpt_BR
dc.date.issued2011pt_BR
dc.identifier.issn1413-3555pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/61896pt_BR
dc.description.abstractContextualização: A necessidade de identificação precoce de alterações posturais, sem expor as pessoas à radiação constante, tem estimulado a construção de instrumentos para medir as curvaturas da coluna vertebral. Objetivo: Verificar a validade, repetibilidade e reprodutibilidade dos ângulos das curvaturas sagitais da coluna vertebral, obtidos por meio de um arcômetro adaptado, comparando-oscom os ângulos de Cobb (AC) das respectivas curvaturas, obtidos por meio de exames radiográficos. Métodos: Cinquenta e dois indivíduos foram submetidos a dois procedimentos destinados a avaliar as curvaturas torácica e lombar: (1) exame de raios-X, a partir do qual os AC de ambas as curvaturas foram obtidos e (2) medição dos ângulos das curvaturas com o arcômetro (AA). Dois avaliadores coletaram os dados usando o arcômetro com as hastes sobre os processos espinhosos T1, T12, L1 e L5, de modo a permitir medidas que, com auxílio de trigonometria, forneceram os AA. Resultados: Encontrou-se correlação muito forte e significativa entre AA e AC (r=0,94, p<0,01), sem diferença significativa (p=0,32) para a curvatura torácica, enquanto, para a curvatura lombar, encontrou-se uma forte e significativa correlação (r=0,71, p<0,01) entre AA e AC, sem diferença significativa (p=0,30). Existe uma correlação muito forte intra-avaliador e inter-avaliador nos AA. Conclusão: O arcômetro permitiu quantificar as curvaturas torácica e lombar, podendo-se considerar as medições válidas, fidedignas e objetivas para uso na avaliação de curvaturas da coluna vertebral no plano sagital.pt_BR
dc.description.abstractBackground: The need for early identification of postural abnormalities without exposing patients to constant radiation has stimulated the development of instruments aiming to measure the spinal curvatures. Objective: To verify the validity, repeatability and reproducibility of angular measures of sagittal curvatures of the spine obtained using an adapted arcometer, by comparing them with Cobb angles of the respective curvatures obtained by using X-rays. Methods: 52 participants were submitted to two procedures designed to evaluate the thoracic and lumbar curvatures: (1) X-ray examination from which the Cobb angles (CA) of both curvatures were obtained, and (2) measuring the angles with the arcometer (AA). Two evaluators collected the data using the arcometer, with the rods placed at T1, T12, L1 and L5 spinous processes levels in a way as to permit linear measurements which, with aid of trigonometry, supplied the AA. Results: There was a very strong and significant correlation between AA and CA (r=0.94; p<0.01), with no-significant difference (p=0.32), for the thoracic curvature. There was a strong and significant correlation for the lumbar curvature (r=0.71; p<0.01) between AA and CA, with no-significant difference (p=0.30). There is a very strong correlation between intra-evaluator and inter-evaluator AA. Conclusion: It was possible to quantify reliably the thoracic and lumbar curvatures with the arcometer and it can thus be considered valid and reliable and for use in evaluating spinal curvatures in the sagittal plane.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoengpt_BR
dc.relation.ispartofRevista brasileira de fisioterapia. Vol. 15, n. 6 (dec. 2011), p. 511-517.pt_BR
dc.rightsOpen Accessen
dc.subjectAvaliaçãopt_BR
dc.subjectEvaluationen
dc.subjectSpineen
dc.subjectColuna vertebralpt_BR
dc.subjectX-raysen
dc.subjectValidade dos testespt_BR
dc.subjectValidity of testsen
dc.subjectPhysical therapyen
dc.titleValidation, repeatability and reproducibility of a noninvasive instrument for mesuring thoracic and lumbar curvature of the spine in the sagittal planept_BR
dc.title.alternativeValidade, repetibilidade, e reprodutibilidade de um instrumento não-invasivo para medição das curvaturas torácica e lombar da coluna vertebral no plano sagital pt
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000821164pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples