dc.description.abstractOs aparelhos de automação em hematologia oferecem alta sensibilidade e precisão na realização do hemograma na rotina do laboratório de hematologia. Para avaliar os critérios de liberação dos hemogramas por interfaceamento direto entre os contadores eletrônicos e o setor de emissão dos laudos, foram examinadas 247 lâminas de hemogramas. Entre essas, 149 lâminas foram consideradas concordantes com os critérios de liberação por interfaceamento direto enquanto 98 foram consideradas não concordantes pelos contadores automatizados Sysmex SE 9500 e Cell Dyn 4000. Dentre os hemogramas concordantes, a microscopia sem acesso aos dados numéricos mostrou alteração em apenas uma lâmina, a qual era clinicamente irrelevante. Por outro lado, entre os 98 hemogramas não concordantes, 32 apresentavam alterações. Os dados encontrados comprovam a satisfatória sensibilidade dos sistemas de automação analisados. As lâminas dos hemogramas não concordantes foram reexaminadas, com o objetivo de avaliar os resultados eletrônicos. Esse fato permitiu a análise das causas das reprovações com sugestões para eventuais simplificações do sistema. O presente trabalho mostrou que os resultados emitidos pelos contadores automáticos analisados apresentam uma alta correlação com a avaliação microscópica. Conclui-se, portanto, que os resultados dos hemogramas liberados pelos aparelhos analisados são satisfatórios e estes aparelhos são confiáveis para a rotina no laboratório de hematologia.pt_BR
dc.description.abstractAutomated equipment used in the hematological laboratory for routine hemograms offers high sensitivity and great accuracy. In order to evaluate the liberation criteria of hemograms by direct interfacing between the electronic counters and the emission of results, 247 hemogram slides were examined. Of these using the Sysmex SE 9500 and Cell Dyn 4000 automated counters, 149 slides were considered concordant with liberation criteria by direct interfacing while 98 were considered non-concordant. Of the concordant hemograms, microscopy without access to the numeric results showed alterations in only one slide, which was considered clinically irrelevant. On the other hand, of the 98 non-concordant hemograms, 32 showed alterations. The results demonstrate the satisfactory sensitivity of the automatic systems analyzed. The slides with the non-concordant hemograms were re-examined, in order to evaluate the electronic results. Thus, it was possible to analyze the causes of the non-concordance and give suggestions for possible simplifications of the system. This study shows that the results emitted by the assessed automatic counters presented a high level of correlation with the microscopy count. Therefore, it can be concluded that the results of the hemograms liberated by the devices are satisfactory and that these devices are reliable for the routine use within the hematological laboratory.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.relation.ispartofRevista brasileira de hematologia e hemoterapia =Brazilian journal of hematology and hemotherapy. São Paulo. Vol. 26, n.3 (2004), p. 159-166pt_BR
dc.rightsOpen Accessen
dc.subjectHemogramen
dc.subjectHemogramapt_BR
dc.subjectAutomationen
dc.subjectCell Dyn 4000en
dc.subjectSysmex SE 9500en
dc.titleAvaliação dos critérios de liberação direta dos resultados de hemogramas através de contadores eletrônicospt_BR
dc.title.alternativeEvaluation of the direct liberation criteria of hemogram results from electronic counters en