dc.contributor.authorOurique, Aline Ferreirapt_BR
dc.contributor.authorContri, Renata Vidorpt_BR
dc.contributor.authorGuterres, Silvia Stanisçuaskipt_BR
dc.contributor.authorBeck, Ruy Carlos Ruverpt_BR
dc.contributor.authorPohlmann, Adriana Raffinpt_BR
dc.contributor.authorMelero, Ana Z.pt_BR
dc.contributor.authorSchaefer, Ulrich F.pt_BR
dc.date.accessioned2013-07-02T01:43:21Zpt_BR
dc.date.issued2012pt_BR
dc.identifier.issn0100-4042pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/72884pt_BR
dc.description.abstractA reliable method using LC-UV to assay mometasone furoate (MF) in creams or nasal sprays using the same chromatographic conditions was set up. Methanol:water 80:20 (v/v) (1.0 mL min-1) was used as mobile phase. MF was detected at 248 nm and analyzed in a concentration range from 1.0 to 20.0 μg mL-1. The method provided acceptable theoretical plates, peak simmetry, peak tailing factor and peak resolution a short run (5 min). The method showed specificity, good linearity (r = 0.9999) and the quantification limit was 0.379 μg mL-1. Furthermore, the method was precise (RSD < 2.0%), accurate (recovery > 97%) and robust.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoengpt_BR
dc.relation.ispartofQuímica nova. São Paulo. Vol. 35, n. 4, (2012), p. 818-821pt_BR
dc.rightsOpen Accessen
dc.subjectPharmaceuticalsen
dc.subjectProdutos farmacêuticospt_BR
dc.subjectCromatografia liquidapt_BR
dc.subjectLiquid chromatographyen
dc.subjectMometasonapt_BR
dc.subjectMometasoneen
dc.titleSet-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage formspt_BR
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000837761pt_BR
dc.type.originNacionalpt_BR