Mostrar registro simples

dc.contributor.advisorSouza, André João dept_BR
dc.contributor.authorMarchiori, Marcelo Mennetpt_BR
dc.date.accessioned2013-11-02T01:58:32Zpt_BR
dc.date.issued2013pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/79829pt_BR
dc.description.abstractA determinação da rugosidade é parte fundamental para a classificação da qualidade de uma superfície. Assim, iniciou-se este trabalho realizando-se estudos a respeito de seus métodos de medição. Devido à grande adaptabilidade e à velocidade dos métodos a laser, os estudos foram direcionados para estes tipos de técnicas de medição. Verificou-se que esses dispositivos vinculavam-se a sistemas em que o laser refletido era analisado através de sistemas com detectores do tipo CCD, em que a imagem refletida era analisada num todo. Assim, a bibliografia trouxe inspiração para mensurar a rugosidade de uma superfície gerada por torneamento horizontal, a partir da intensidade laser refletida. Propôs-se, então, um método baseado exclusivamente, na intensidade do sinal que era refletido pela superfície em estudo, a contar de uma incidência normal, já que aos autores ressaltavam que quanto maior a rugosidade da superfície menor seria o sinal refletido por ela. O sistema foi montado e sua capacidade de diferenciar distintas rugosidades foi testada. Então foram produzidas amostras com diferentes rugosidades, a fim de se obter uma função que pudesse correlacionar o sinal laser com a respectiva rugosidade (medida esta feita em rugosímetro de agulha). A função de transferência encontrada foi testada em amostras dissemelhantes das que a geraram, com o intuito de comprovar sua eficácia. Amostras fabricadas com ferramentas distintas de corte também foram produzidas e submetidas ao mesmo procedimento. As funções de transferência geradas alcançaram sucesso na previsão da rugosidade em, no máximo, 16,6% dos pontos, considerando uma margem de erro de 20%. A seguir, procurando-se os motivos que pudessem ter causado este percentual, levantou-se a possibilidade de estarem ocorrendo efeitos ópticos capazes de causar interferências devido às irregularidades na superfície. Efeitos capazes de degenerarem o sinal refletido. A comprovação de que o sinal eventualmente poderia estar sendo perturbado aconteceu através de referência bibliográfica e de imagens obtidas por microscopia eletrônica de varredura, em que se pôde observar a existência de estruturas na face das amostras que seriam isolada ou conjuntamente capazes de causar os efeitos citados.pt_BR
dc.description.abstractThe determination of the roughness is a key for a good classification of a surface. Thereby, the work was started with a study about the roughness measurements methods. Due to the great adaptability and speed of laser methods, the studies were directed to these kinds of measurement techniques. It was observed in the literature that these laser devices were linked to systems where the reflected laser was analyzed by systems with CCD detectors, where the reflected image was entirely analyzed. Hence, the bibliography brought inspiration to measure the surface roughness generated by axial turning from the intensity of the reflected laser. It was proposed then a measurement method exclusively based on the intensity of the signal that was reflected by the surface under study, because the authors noted that as the roughness of surface became bigger as the signal reflected is became smaller. The proposed system has been assembled and ability to distinguish different roughness was tested successfully. Then samples were produced with different roughness in order to obtain a function that would correlate the laser signal with its roughness (this measurement is made by tactile measurement instrument). The transfer function obtained was tested on different samples that generated in order to prove its efficacy. Samples produced with different cutting tools were also produced and subjected to the same procedure. The transfer functions reached a successful prediction of the roughness maximum for 16.6% of the points assuming a margin of error of 20%. So, looking up the reasons that could have caused this percentage we think the possibility as the occurrence of some optical effects that can cause interference due to irregularities on the surface. These optical effects can degenerate the reflected signal. The proof that the signal could possibly be corrupted was made by the bibliographic references and some images obtained by scanning electron microscopy in which they could observe the existence of structures on the sample surfaces that would can be a reason for these effects individually or together.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectRoughness averageen
dc.subjectUsinagempt_BR
dc.subjectTorneamentopt_BR
dc.subjectLaser measuring systemen
dc.subjectReflected signalen
dc.subjectRugosidade de superfíciept_BR
dc.subjectInterferenceen
dc.titleEstudo de um sistema de medição a laser na análise da textura da superfície gerada por torneamentopt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb000897449pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia Mecânicapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2013pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples