Repositório Digital

A- A A+

Lodenafil carbonate tablets : optimization and validation of a capillary zone electrophoresis method

.

Lodenafil carbonate tablets : optimization and validation of a capillary zone electrophoresis method

Mostrar registro completo

Estatísticas

Título Lodenafil carbonate tablets : optimization and validation of a capillary zone electrophoresis method
Autor Codevilla, Cristiane Franco
Ferreira, Pâmela Cristina L.
Sangoi, Maximiliano da Silva
Froehlich, Pedro Eduardo
Bergold, Ana Maria
Resumo Um método simples de eletroforese capilar de zona (CZE) foi desenvolvido e validado para análise de carbonato de lodenafila em comprimidos. A metodologia de superfície de resposta foi utilizada para a otimização do pH, concentração do tampão, voltagem e temperatura. O método utilizou como eletrólito, tampão borato 50 mmol L-1, pH 10, voltagem de 15 kV. A separação foi efetuada em capilar de sílica fundida mantida a 32,5 oC e o comprimento de onda de detecção foi de 214 nm. O método foi validado, demonstrando especificidade, linearidade (r = 0,9995), precisão (desvio padrão relativo inferior a 2%) e exatidão (99,95%). O método demonstrou ser robusto, através de avaliação por planejamento fatorial fracionário. O método CZE proposto foi aplicado com sucesso para a análise quantitativa de carbonato de lodenafila em comprimidos e os resultados, comparados com os métodos por cromatografia líquida de alta eficiência e espectrofotometria no ultravioleta, não apresentaram diferença significativa
Abstract A simple capillary zone electrophoresis (CZE) method was developed and validated for the analysis of lodenafil carbonate in tablets. Response surface methodology was used for optimization of the pH and concentration of the buffer, applied voltage and temperature. The method employed 50 mmol L-1 borate buffer at pH 10 as background electrolyte with an applied voltage of 15 kV. The separation was carried out in a fused-silica capillary maintained at 32.5 oC and the detection wavelength was 214 nm. The method was validated showing specificity, linearity (r = 0.9995), precision (relative standard deviation less than 2%) and accuracy (99.95%). The method proved to be robust by a fractional factorial design evaluation. The proposed CZE method was successfully applied for the quantitative analysis of lodenafil carbonate in tablets and the results compared to the high performance liquid chromatography and ultraviolet spectrophotometric methods, showed non-significant differences.
Contido em Journal of the Brazilian Chemical Society. São Paulo. Vol. 23, n. 11 (nov. 2012), p. 2114-2121
Assunto Carbonato de lodenafila
Eletroforese capilar
Validação : Métodos de análise de fármacos
[en] capillary zone electrophoresis
[en] experimental design
[en] lodenafil carbonate
[en] optimization
[en] validation
Origem Nacional
Tipo Artigo de periódico
URI http://hdl.handle.net/10183/88086
Arquivos Descrição Formato
000904423.pdf (947.9Kb) Texto completo Adobe PDF Visualizar/abrir

Este item está licenciado na Creative Commons License

Este item aparece na(s) seguinte(s) coleção(ões)


Mostrar registro completo

Percorrer



  • O autor é titular dos direitos autorais dos documentos disponíveis neste repositório e é vedada, nos termos da lei, a comercialização de qualquer espécie sem sua autorização prévia.
    Projeto gráfico elaborado pelo Caixola - Clube de Criação Fabico/UFRGS Powered by DSpace software, Version 1.8.1.