Mostrar registro simples

dc.contributor.authorCodevilla, Cristiane Francopt_BR
dc.contributor.authorFerreira, Pâmela Cristina L.pt_BR
dc.contributor.authorSangoi, Maximiliano da Silvapt_BR
dc.contributor.authorFroehlich, Pedro Eduardopt_BR
dc.contributor.authorBergold, Ana Mariapt_BR
dc.date.accessioned2014-03-01T01:54:38Zpt_BR
dc.date.issued2012pt_BR
dc.identifier.issn0103-5053pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/88086pt_BR
dc.description.abstractUm método simples de eletroforese capilar de zona (CZE) foi desenvolvido e validado para análise de carbonato de lodenafila em comprimidos. A metodologia de superfície de resposta foi utilizada para a otimização do pH, concentração do tampão, voltagem e temperatura. O método utilizou como eletrólito, tampão borato 50 mmol L-1, pH 10, voltagem de 15 kV. A separação foi efetuada em capilar de sílica fundida mantida a 32,5 oC e o comprimento de onda de detecção foi de 214 nm. O método foi validado, demonstrando especificidade, linearidade (r = 0,9995), precisão (desvio padrão relativo inferior a 2%) e exatidão (99,95%). O método demonstrou ser robusto, através de avaliação por planejamento fatorial fracionário. O método CZE proposto foi aplicado com sucesso para a análise quantitativa de carbonato de lodenafila em comprimidos e os resultados, comparados com os métodos por cromatografia líquida de alta eficiência e espectrofotometria no ultravioleta, não apresentaram diferença significativapt_BR
dc.description.abstractA simple capillary zone electrophoresis (CZE) method was developed and validated for the analysis of lodenafil carbonate in tablets. Response surface methodology was used for optimization of the pH and concentration of the buffer, applied voltage and temperature. The method employed 50 mmol L-1 borate buffer at pH 10 as background electrolyte with an applied voltage of 15 kV. The separation was carried out in a fused-silica capillary maintained at 32.5 oC and the detection wavelength was 214 nm. The method was validated showing specificity, linearity (r = 0.9995), precision (relative standard deviation less than 2%) and accuracy (99.95%). The method proved to be robust by a fractional factorial design evaluation. The proposed CZE method was successfully applied for the quantitative analysis of lodenafil carbonate in tablets and the results compared to the high performance liquid chromatography and ultraviolet spectrophotometric methods, showed non-significant differences.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoengpt_BR
dc.relation.ispartofJournal of the Brazilian Chemical Society. São Paulo. Vol. 23, n. 11 (nov. 2012), p. 2114-2121pt_BR
dc.rightsOpen Accessen
dc.subjectcapillary zone electrophoresisen
dc.subjectCarbonato de lodenafilapt_BR
dc.subjectexperimental designen
dc.subjectValidação : Métodos de análise de fármacospt_BR
dc.subjectEletroforese capilarpt_BR
dc.subjectlodenafil carbonateen
dc.subjectoptimizationen
dc.subjectvalidationen
dc.titleLodenafil carbonate tablets : optimization and validation of a capillary zone electrophoresis methodpt_BR
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000904423pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples