Mostrar registro simples

dc.contributor.advisorVale, Maria Goreti Rodriguespt_BR
dc.contributor.authorBorges, Aline Rochapt_BR
dc.date.accessioned2014-03-15T01:52:52Zpt_BR
dc.date.issued2013pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/88557pt_BR
dc.description.abstractNeste trabalho, foi investigada a viabilidade do use da analise direta por espectrometria de absorcdo atomica corn forno de grafite (GF AAS) para a determinacdo de metais em fertilizantes e calcario. Foi desenvolvido um metodo para a determinacdo de chumbo utilizando analise por suspensao (S1S) por GF AAS corn corretor de fundo baseado no efeito Zeeman (S1S-GF AAS-ZBC). As interferencias espectrais observadas foram, em parte, resolvidas usando espectrometria de absorcao atomica de alta resolucao corn fonte continua (HR-CS AAS) corn aplicacao de correcdo por minimos quadrados. Posteriormente, foi desenvolvido um metodo para a determinacao de cadmio por S1S-HR-CS GF AAS, neste caso, o sinal de fundo foi resolvido corn a aplicacao da correcdo automatica e nao foi observada interferencia espectral. A analise direta de solidos (SS) foi utilizada na determinacao de cromo e talio por GF AAS-ZBC, e os resultados, comparados por SS-HRCS GF AAS, na maioria dos casos, foram compativeis. Entretanto, na determinacao de tali°, devido a alguma interferencia espectral desconhecida, algumas amostras somente puderam ser analisadas por SS-HR-CS GF AAS. Nenhuma das amostras investigadas apresentou concentracao de chumbo, cadmio e cromo maior do que o estipulado pela legislacao brasileira, a qual nab estabelece um limite maximo para tali°.pt_BR
dc.description.abstractIn this work, was investigated the feasibility of using analysis direct graphite furnace atomic absorption spectrometry (GF AAS) for the determination of metals in fertilizer and limestone. A method was developed for the determination of lead using slurry sampling (S1S) with GF AAS with Zeeman-effect background correction (S1S-GF AAS-ZBC). The observed spectral interferences could be overcome, in part, using high-resolution continuum source (HR-CS AAS) with least-squares background correction. Posteriorly, a method was developed for the determination of cadmium using S1S-HR-CS GF AAS; in this case the background signal could be resolved using automatic correction and no spectral interferences were observed. The direct solid sample analysis (SS) was used for the determination of chromium and thallium with GF AAS-ZBC, and the results were compared with SS-HR-CS GF AAS. In most cases, the values were compatible; however, in some samples, thallium could only be determined using SS-HR-CS GF AAS due to an unknown spectral interference. None of the investigated samples had a cadmium, chromium or lead concentration exceeding the limits given by Brazilian legislation; no limits are given for thallium.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectEspectrometria de absorção atômicapt_BR
dc.subjectEspectrometria de absorcao atomica em forno de grafitept_BR
dc.subjectMetais : Determinaçãopt_BR
dc.titleDeterminação de metais em fertilizantes e calcário utilizando análise direta por espectrometria de absorção atômica com forno de grafite.pt_BR
dc.typeTesept_BR
dc.identifier.nrb000912358pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentInstituto de Químicapt_BR
dc.degree.programPrograma de Pós-Graduação em Químicapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2013pt_BR
dc.degree.leveldoutoradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples