Mostrar el registro sencillo del ítem

dc.contributor.advisorCybis, Luiz Fernando de Abreupt_BR
dc.contributor.authorSegredo, Artur Estacha Armindo Estachapt_BR
dc.date.accessioned2016-07-15T02:16:24Zpt_BR
dc.date.issued2014pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/143599pt_BR
dc.description.abstractA drenagem ácida de mina (DAM) gerada no processo de mineração de carvão, na presença de minerais sulfetados, tem provocado danos ambientais significativos no ecossistema de sua abrangência. Tecnologia de tratamento ativo baseada em processos de Neutralização, Precipitação e Sedimentação tem sido empregada para atenuar a carga de poluentes no efluente, antes do seu descarte em corpos receptores. A mesma, apesar da sua eficiência vem se mostrando bastante onerosa quando aplicada durante um longo período, devido aos custos com insumos, manutenção, potencial humano e energia. Nos últimos anos, vem sendo desenvolvidos sistemas que socorrem-se da ocorrência natural de processos químicos, biológicos e físicos para purificar água de mina contaminada. Estes são designados sistemas passivos, cuja implantação e funcionamento tem se mostrado menos onerosa em relação ao sistema ativo. Capão da Roça, situado no município de Charqueadas é uma das regiões do Brasil onde ocorre contaminação de solos e rios pela DAM gerada a partir de um depósito de rejeitos. Aplicando o fluxograma recomendado por diversos autores para a seleção do sistema passivo, tomando em conta as características do efluente achou-se viável instalar um canal aberto de calcário para o tratamento da DAM do Capão da Roça em virtude de a mesma apresentar acidez maior que a alcalinidade, oxigênio dissolvido maior que 5mg/l, Fe+3 maior que 25% em relação ao Fe2+. A quantidade de efluente e a declividade do terreno da área estudada permite que se opere com vazão maior que 12m3/h no sistema passivo. De acordo com a acidez do efluente foi determinado o tempo de detenção de 1hora para o tratamento da DAM no sistema. A partir de estudos similares sobre o uso de calcário em sistemas passivos, encontrou-se a massa de 338,6 toneladas para o empreendimento funcionar em 10 anos, considerando uma dissolução de calcário de 100%, num canal com 10% de declividade, 1m de profundidade e 2, 5 metros de largura para tamponar uma solução de DAM com vazão de 1000 L.min-1 num canal de 47metros de cumprimento. De acordo com cálculos baseados num modelo empírico, ficou demonstrado que o diâmetro e área de superfície do calcário poderão diminuir ao longo do tempo, considerado a sua dissolução.pt_BR
dc.description.abstractAcid mine drainage (AMD) generated in the coal mining process in the presence of sulfide minerals, have been causing significant environmental damages to the ecosystem of its coverage. Active treatment technology based on neutralization, precipitation and sedimentation processes, has been used to alleviate the load of pollutants in the effluent prior to discharges into receiving bodies. Despite their efficiency has proved quite costly when applied over a long period due to input costs, maintenance, manpower and energy. In recent years project defined 'passive treatment' has been developed as the improvement of water quality using only naturally occurring chemical, biological and physical processes, hence, the deployment and operation have been less costly compared to the active systems. Capão da Roça, located in the municipality of Charqueadas is one of the regions of Brazil where occurs contamination of soils and rivers by AMD generated from a waste dump. Using the flowchart recommended by several authors for selecting the passive system, taking into account the wastewater characteristics, was found to be feasible to install an open limestone channel for the treatment of AMD because it has higher acidity than alkalinity, dissolved oxygen greater than 5mg / l, Fe3+ greater than 25 % in relation to Fe2+. The amount of effluent and the slope of the study area terrain allows to operate with a flow rate greater than 12m3/ h in the passive system. According to the acidity of the effluent was determined retention time of 1 hour for the treatment of the AMD system. From similar studies on the use of limestone in passive systems, was found the mass of 338.6 tons for the enterprise operating over 10 years, assuming a 100% limestone dissolution channel with a 10% slope, 1 meter deep and 2,5 meters wide to buffer an AMD solution with a flow rate of 1000 L.min-1 in channel with 47 meters of length. According to the calculations based on empirical model, it was shown that the diameter and the surface area of limestone may decline over time, considering its dissolution.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectCarvãopt_BR
dc.subjectCoalen
dc.subjectAcid mine drainageen
dc.subjectDrenagem ácida de minaspt_BR
dc.subjectCapão da Roça (Charqueadas, RS)pt_BR
dc.subjectPassive systemen
dc.subjectOpen channel limestoneen
dc.subjectSizing of passive systemen
dc.titleProposta de um sistema passivo para o tratamento da drenagem ácida de mina gerada no depósito de rejeitos de Capão da Roça, Charqueadas/RS, Copelmi mineração Ltdapt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb000981481pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentInstituto de Pesquisas Hidráulicaspt_BR
dc.degree.programPrograma de Pós-Graduação em Recursos Hídricos e Saneamento Ambientalpt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2014.pt_BR
dc.degree.levelmestradopt_BR


Ficheros en el ítem

Thumbnail
   

Este ítem está licenciado en la Creative Commons License

Mostrar el registro sencillo del ítem