Mostrar registro simples

dc.contributor.advisorReguly, Afonsopt_BR
dc.contributor.authorSantos, Fellipe Cros dospt_BR
dc.date.accessioned2018-05-17T02:26:51Zpt_BR
dc.date.issued2017pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/178408pt_BR
dc.description.abstractAs ligas de ferro fundido branco alto cromo (FFBAC) da norma ASTM A-532 são comumente utilizadas em peças que necessitam de elevada resistência ao desgaste. Tal escolha acontece devido à elevada dureza apresentada por tais materiais, o que propicia maior vida útil dos componentes. Entretanto, uma vez que o teor de cromo utilizado nos FFBAC possui grande influência no custo das peças, é importante garantir que os tratamentos térmicos (TOTO’s) aplicados estejam otimizados para cada composição de liga. Buscando atuar nesse sentido, esta dissertação analisou a utilização de diferentes tempos e temperaturas de patamar em TOTO’s de desestabilização da austenita para duas ligas da norma ASTM A-532 (ligas com 20% e 25%Cr). Após tais procedimentos, foram estudadas a dureza e a resistência ao desgaste, tanto para algumas das amostras tratadas quanto para seis amostras de FFBAC fornecidas por diversas fundições nacionais. Os resultados demonstraram a existência de uma temperatura que otimiza a dureza da liga, possibilitando incrementos desta propriedade nas amostras tratadas em valores de até 37% (considerando a dureza inicial na condição “bruto de fusão”). Com relação ao tempo de patamar, verificou-se que o mesmo apresentou pouca influência no incremento de dureza, apresentando variações máximas inferiores à 4% para tratamentos variando entre 30 minutos à 6 horas de duração, resultado que destoou daquele indicado pela literatura. Além disso, verificou-se que uma liga com 19,6 %Cr pode apresentar uma dureza até 11% maior do que o verificado para ligas comerciais Nesta comparação, apesar da liga comercial possuir menor teor de carbono, ficou evidenciado o indicativo de que as peças consideradas neste estudo e oriundas de fundições nacionais não otimizam os resultados de seus TOTO’s. A resistência ao desgaste, por sua vez, demonstrou não depender apenas da macrodureza das amostras, mas também de outras características como tamanho, distância e continuidade dos carbonetos primários, o que explica a obtenção de resultados similares de perda de massa no ensaio abrasivo para amostras que possuem durezas diferindo em cerca de 12% porém possuindo tamanho de microconstituintes similares. Por fim, observou-se que ligas com maiores teores de cromo e menores teores de carbono apresentam menores valores de dureza e resistência ao desgaste, o que viabiliza uma aplicação com maior vida útil e menor custo.pt_BR
dc.description.abstractThe high chromium white cast iron alloys from ASTM A-532 are commonly used in parts which wear resistance are required. This choice happens due the great hardness showed by these alloys, what propitiates a higher lifetime for the components. However, since chromium content has great influence in the cost of the parts, it is important ensure that the apply heat treatments are optimized for each alloy composition. Thus this dissertation analyzed the application of different heat treatment cycles on the austenite destabilization for two ASTM A-532 alloys (20%Cr and 25%Cr). After the heat treatment, hardness, wear resistance and microstructure were analyzed, both for some of the treated samples as for six samples provided by different manufactures in Brazil. The results showed the existence of a temperature that optimizes the alloy hardness, allowing increases on this property in values up to 37% (considering the initial hardness of the “as cast” condition) Concerning the time of heat treatment, was verified that this parameter has low influence in the increase on hardness, showing maximum variations lower than 4% in treatments with times coming from thirty minutes until six hours, results that does not match that one’s indicated by the literature. Besides that, it was verified that an alloy with 19,6%Cr can present a hardness 11% greater than that verified in commercial. In this comparation, although the commercial alloy having lower carbon content, was evidenced that the parts from the Brazilians companies which were considered in this study, does not have an optimum heat treatment. The wear resistance was not only depend of the sample hardness, but also of other characteristics as size, distance and continuity of the primary carbides, which explain the results of similar mass loss in the abrasive test for samples with hardness differing about 12%, but with similar size of microconstituents. Finally, it was observed that alloys with higher chromium and low carbon content shows lower hardness and wear resistance values than alloys with low percentages of chromium, what enable an application with larger lifetime and lower cost.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectFerro fundido brancopt_BR
dc.subjectWhite cast ironen
dc.subjectAbrasive wear resistanceen
dc.subjectResistência ao desgastept_BR
dc.subjectHardnessen
dc.subjectDurezapt_BR
dc.subjectAustenite destabilizationen
dc.subjectDesgaste abrasivopt_BR
dc.titleAvaliação da influência do teor de cromo e do tratamento térmico de desestabilização da austenita na dureza e resistência ao desgaste abrasivo de ferros fundidos brancospt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb001064515pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia de Minas, Metalúrgica e de Materiaispt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2017pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples