Show simple item record

dc.contributor.authorBenetti, Antônio Dominguespt_BR
dc.contributor.authorQueiroz, Sérgio Carlos Bernardopt_BR
dc.contributor.authorDi Bernardo, Luizpt_BR
dc.contributor.authorDantas, Angela Di Bernardopt_BR
dc.contributor.authorSilva, Giulliano Guimarãespt_BR
dc.date.accessioned2018-10-27T03:12:55Zpt_BR
dc.date.issued2018pt_BR
dc.identifier.issn0101-6040pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/184145pt_BR
dc.description.abstractDevido à crise hídrica atual e tendo em vista o desenvolvimento e a otimização de tecnologias de tratamento de águas para abastecimento público que estejam contaminadas com microrganismos, toxinas e microcontaminantes, o presente trabalho foi realizado com o objetivo de estudar a Dupla Filtração (DF) como alternativa de tratamento de água eutrofizada na região Norte do Brasil. Foi montada uma instalação piloto de dupla filtração composta pelas unidades de pré-cloração, adsorção em carvão ativado pulverizado, filtro ascendente de pedregulho e filtro rápido descendente de areia, os quais funcionaram com taxas de filtração de 120 e 180 m3.m-2.d-1, respectivamente. A água de estudo apresentou densidade de cianobactérias da ordem de 105 cel.mL-1. Os resultados obtidos mostraram que o tratamento com pré- -oxidação com cloro, adsorção em carvão ativado pulverizado, coagulação e dupla filtração produziu água com valores de COT abaixo de 2,0 mg.L-1, turbidez inferior a 0,50 uT, e remoção de células de cianobactérias maior que 99%. As concentrações máximas de subprodutos orgânicos halogenados (SOH) encontrados na água tratada foram menores que os valores limites da Portaria 2914/2011 do Ministério da Saúde.pt_BR
dc.description.abstractDue to the water crisis observed during the last years in Brazil and the development and optimization of water treatment technologies for public supply of contaminated sources with microorganisms, toxins and microcontaminants, this research work was carried out aiming the study of double filtration technology as an alternative to the treatment of eutrophicated water in the north region of Brazil. A pilot plant was assembled, which consisted of units of pre chlorination, adsorption in powdered activated carbon, coagulation, upflow gravel prefiltration and downflow rapid sand filtration with filtration rates of 120 and 180 m3.m-2.d-1, respectively. Concentration of cyanobacteria in the study water was up to 105cells.mL-1. The results showed the production of final water with total organic carbon concentration lower than 2.0 mg.L-1, turbidity less than 0.5 TU, cyanobacteria removal higher than 99% and concentration of trihalomethanes below the standard limit shown in the Regulatory Ordinance no. 2914/2011 of the Ministry of Health of Brazilen
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofRevista DAE. Vol. 66, n. 212 ( set. 2018), p. 41-60pt_BR
dc.rightsOpen Accessen
dc.subjectWater treatmenten
dc.subjectFiltraçãopt_BR
dc.subjectTratamento da águapt_BR
dc.subjectDouble filtrationen
dc.subjectPowdered activated carbonen
dc.subjectCianobactériaspt_BR
dc.subjectCarvão ativadopt_BR
dc.subjectCyanobacteriaen
dc.subjectCloropt_BR
dc.titleDupla filtração para o tratamento de água eutrofizada na região norte do Brasilpt_BR
dc.title.alternativeDouble filtration for the treatment of eutrophic water in the north region of Brazil en
dc.typeArtigo de periódicopt_BR
dc.contributor.eventAESABESP. Encontro técnico. (29 : 2018 : São Paulo)pt_BR
dc.identifier.nrb001078973pt_BR
dc.type.originNacionalpt_BR


Files in this item

Thumbnail
   

This item is licensed under a Creative Commons License

Show simple item record