Mostrar registro simples

dc.contributor.advisorJardim, Juliana Jobimpt_BR
dc.contributor.authorMoura, Helora Freitaspt_BR
dc.date.accessioned2021-05-13T04:27:51Zpt_BR
dc.date.issued2020pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/220918pt_BR
dc.description.abstractObjetivo: Avaliar a eficiência do método de “starch tubing” para a realização do teste microcisalhamento (µSBS), por meio de restaurações confeccionadas através da técnica incremental em dentina e em esmalte de dentes bovinos, utilizando uma resina Bulk Fill e o composto Cention® N. Materiais e métodos: A superfície vestibular de 96 dentes bovinos foi planificada expondo esmalte e dentina nos espécimes. Houve a distribuição aleatória dos espécimes nos grupos: Resina Filtek™ One Resina Bulk Fill 3M™ (grupo G1), Cention® N fotopolimerizado, Ivoclar, Vivadent (grupo G2) e Cention® N autopolimerizado, Ivoclar, Vivadent (grupo G3). Cada grupo apresentou 16 superfícies de esmalte planificado e 16 com dentina exposta. Duas restaurações foram realizadas em cada superfície utilizando tubos de amido com 1,35mm de diâmetro interno e altura aproximada de 2mm (técnica do “starch tubing”), sendo preenchidos com os materiais restauradores por meio da técnica incremental. Foi realizado o condicionamento ácido seletivo nas superfícies de esmalte e todos os espécimes receberam aplicação de adesivo (Single Bond Universal, 3M ESPE, St Paul, Estados Unidos). Os espécimes foram estocados em água destilada a 37°C por 24h e submetidos ao teste de resistência de união ao microcisalhamento em uma máquina de ensaio universal a uma velocidade de 0,5 mm/min. Os valores de resistência de união ao microcisalhamento foram analisados estatisticamente por Shapiro-Wilk, WilcoxonMann-Whitney, ANOVA e Kruskal-Wallis. As fraturas foram avaliadas em estereoscópio (magnificação de 8x). Resultados: Em dentina, dos grupos avaliados apenas o grupo G1 exibiu dados com distribuição normal, apresentando a maior média de força de resistência de união ao microcisalhamento (12,57 MPa ± 4,7; p-valor = 0,2), a homogeneidade mais elevada (variabilidade de 32%), a menor taxa de falha pré-teste (3,85%) e o menor coeficiente de variação (0,32). Em esmalte, todos os grupos testados apresentaram dados com distribuição normal, sendo o grupo G2 aquele com a maior média de resistência de união ao microcisalhamento (13,04 MPa ± 5,09; p-valor = 0,38), a homogeneidade mais elevada (variabilidade de 39%), a menor taxa de falhas pré-teste (20%) e o menor coeficiente de variação (0,39). As fraturas avaliadas foram predominantemente classificadas como adesivas.Conclusão: A técnica “starch tubing” associada a técnica de inserção testada para a confecção dos espécimes destinados ao µSBS é efetiva na avaliação do desempenho da Resina Filtek™ One Resina Bulk Fill 3M™ em dentina, porém apresenta baixa eficiência na análise do material Cention® N Ivoclar, Vivadent.pt_BR
dc.description.abstractObjective: To evaluate the efficiency of the “starch tubing” method for performing the micro-shear test (µSBS), using restorations made using the incremental technique in dentin and enamel of bovine teeth, using Bulk Fill resin and the Cention® N. Materials and methods: The buccal surface of 96 bovine teeth was planned to expose enamel and dentin. Each specimen was randomly distributed in the groups: Filtek ™ One resin Bulk Fill 3M ™ resin (group G1), light cured Cention® N, Ivoclar, Vivadent (group G2) and self-cured Cention® N, Ivoclar, Vivadent (group G3). Each group had 16 flat enamel and 16 exposed dentin surfaces (n = 16). Two restorations were performed on each surface using starch tubes (1.35 mm internal diameter and an approximate height of 2 mm -“starch tube” technique), being filled with restorative materials using the incremental technique. The selected acid etching was carried out on the enamel surfaces, and in all samples, an adhesive was applied (Universal Bond Universal, 3M ESPE, St Paul, United States). The specimens were stored in distilled water at 37 °C for 24 hours and subjected to the microshear bond strength test in a universal testing machine at a speed of 0.5 mm / min. The values of micro-shear bond strength were statistically analyzed by Shapiro-Wilk, Wilcoxon-Mann-Whitney, ANOVA and Kruskal-Wallis. The fractureswere evaluated using a stereoscope (8x magnification). Results: In dentin, of the groups analyzed, only the G1 group exhibited data with normal distribution, the highest mean of microshear bond strength (12.57 MPa ± 4.7; p-value = 0.2), the highest homogeneity (32% variability), a lower pre-test failure rate (3.85%), and the lowest variation coefficient (0.32). In enamel, all the tested groups presented data with normal distribution, with the G2 group being the one with the highest mean of microshear bond strength (13.04 MPa ± 5.09; p-value = 0.38), the highest homogeneity (39% variability), a lower pre-test failure rate (20%), and the lowest variation coefficient (0.39). The evaluated fractures were predominantly classified as adhesive. Conclusion: The “starch tubing” technique associated with the tested insertion technique to manufacture of specimens destined to µSBS is effective in evaluating the performance of Filtek ™ One Resin Bulk Fill 3M ™ resin on the dentin substrate. However, it has low efficiency in the analysis of the Cention® N Ivoclar, Vivadent material.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectAnálise de variânciapt_BR
dc.subjectAnalysis of varianceen
dc.subjectDental enamelen
dc.subjectEsmalte dentáriopt_BR
dc.subjectResinas compostaspt_BR
dc.subjectComposite resinsen
dc.titleAnálise do método de confecção de espécimes submetidos ao teste de resistência de união ao microcisalhamentopt_BR
dc.title.alternativeAnalysis of the confection method of specimens undergoing microshear bond strength test en
dc.typeDissertaçãopt_BR
dc.identifier.nrb001124401pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.programPrograma de Pós-Graduação em Odontologia / Clínica Odontológica com ênfase em Dentística/Cariologia.pt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2020pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples