dc.description.abstractO presente estudo foi realizado no município de Carlos Barbosa, localizado na região nordeste do estado do RS, que é abastecido exclusivamente por águas subterrâneas do Sistema Aquífero Serra Geral (SASG). Neste município foi instalado um sistema de monitoramento automatizado, denominado de SIGAS, em 12 dos 15 poços tubulares que captam água do SASG e são utilizados pela CORSAN para o abastecimento público de água no munícipio. O SIGAS monitora volume, vazão e tempo de bombeamento de 15 em 15 minutos e nível de água de 1 em 1 minuto. Foram analisados os dados coletados em 3 poços dos 12 que possuem o sistema. Os dados coletados indicaram que os 3 poços estão trabalhando, na maior parte do período monitorado, acima do tempo de bombeamento projetado, com tempos sem bombeamento operados de forma descontínua. O SIGAS se demostrou um sistema satisfatório para o monitoramento de poços tubulares, inseridos no Sistema Aquífero Serra Geral e utilizados para o abastecimento público, possibilitando a identificação da influência da demanda na operação dos mesmos e o reflexo desta operação nos níveis de água do aquífero no poço. Devido à frequência de coleta de dados e o fácil acesso aos mesmos pelo órgão gestor dos poços, o SIGAS se demostrou ser uma ferramenta de utilidade impar na gestão dos poços.pt_BR
dc.description.abstractThis study was fulfilled in the city of Carlos Barbosa, located in northeastern Rio Grande do Sul state, which is supplied exclusively by groundwater from the Serra Geral Aquifer System (SASG). In this municipality it was installed an automated monitoring system, denominated SIGAS in 12 of the 15 wells that capture water from SASG and are used by CORSAN to the public water supply in the municipality. The SIGAS monitors volume, flow rate and pumping time 15 in 15 minutes and level of water in 1 in 1 minute. Were analyzed data collected in 3 wells 12 having the system. The data collected indicated that the 3 wells are working, in most of the monitored period, above the pumping time designed, operated with without pumping time discontinuously. The SIGAS proved to be a satisfactory system for monitoring wells, inserted in the Serra Geral Aquifer System and used for public supply, enabling the identification of the influence demand in the operation thereof, and the reflection of this operation we aquifer water levels well. Due to data collection frequency and easy access thereof by the managing body of the wells, the SIGAS shown to be an odd utility tool in the management of the wells.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofÁguas subterrâneas (São Paulo. 1978). Vol. 30, n. 3 (2016), p. 455-474pt_BR
dc.rightsOpen Accessen
dc.subjectQuantitative monitoringen
dc.subjectMonitoramento : Sistemaspt_BR
dc.subjectFractured aquifersen
dc.subjectAquíferos fraturadospt_BR
dc.subjectGroundwateren
dc.subjectÁguas subterrâneaspt_BR
dc.subjectSerra Geral, Sistema Aquíferopt_BR
dc.titleImplantação e uso de um sistema de monitoramento automatizado para avaliação da produção de poços em região de ocorrência do sistema aquífero Serra Geralpt_BR
dc.title.alternativeImplementation and use of an automated monitoring system for wells production evaluation in occurrence region of Serra Geral Aquifer System en
dc.typeArtigo de periódicopt_BR