Clinical evaluation of the flotrac/vigileo™ system for continuous cardiac output monitoring in patients undergoing regional anesthesia for elective cesarean section : a pilot study

.

Clinical evaluation of the flotrac/vigileo™ system for continuous cardiac output monitoring in patients undergoing regional anesthesia for elective cesarean section : a pilot study

Mostrar registro completo

Estatísticas

Título Clinical evaluation of the flotrac/vigileo™ system for continuous cardiac output monitoring in patients undergoing regional anesthesia for elective cesarean section : a pilot study
Autor Auler Junior, Jose Otavio Costa
Torres, Marcelo L. A.
Cardoso, Mônica M.
Tebaldi, Thais C.
Schmidt, André Prato
Kondo, Mario M. Kondo
Zugaib, Marcelo
Abstract BACKGROUND: Spinal anesthesia for cesarean delivery may cause severe maternal hypotension and a decrease in cardiac output. Compared to assessment of cardiac output via a pulmonary artery catheter, the FloTrac/VigileoTM system may offer a less invasive technique. The aim of this study was to evaluate cardiac output and other hemodynamic measurements made using the FloTrac/VigileoTM system in patients undergoing spinal anesthesia for elective cesarean section. METHODS: A prospective study enrolling 10 healthy pregnant women was performed. Hemodynamic parameters were continuously obtained at 15 main points: admission to surgery (two baseline measurements), after preload, after spinal anesthesia administration and 4 time points thereafter (4, 6, 8 and 10 min after anesthesia), at skin and uterine incision, newborn and placental delivery, oxytocin administration, end of surgery, and recovery from anesthesia. Hemodynamic therapy was guided by mean arterial pressure, and vasopressors were used as appropriate to maintain baseline values. A repeated measures ANOVA was used for data analysis. RESULTS: There was a significant increase in heart rate and a decrease of stroke volume and stroke volume index up to 10 min after spinal anesthesia (P , 0.01). Importantly, stroke volume variation increased immediately after newborn delivery (P , 0.001) and returned to basal values at the end of surgery. Further hemodynamic parameters showed no significant changes over time. DISCUSSION AND CONCLUSIONS: No significant hemodynamic effects, except for heart rate and stroke volume changes, were observed in pregnant women managed with preload and vasopressors when undergoing elective cesarean section and spinal anesthesia.
Contido em Clinics. São Paulo. Vol. 65, n. 8 (jun. 2010), p. 793-798
Assunto Cesárea
Débito cardíaco
Flo Trac Vigileo
Raquianestesia
Volume sistólico
[en] Cardiac output
[en] Cesarean section
[en] FloTrac/VigileoTM
[en] Spinal anesthesia
[en] Stroke volume
Origem Nacional
Tipo Artigo de periódico
URI http://hdl.handle.net/10183/49791
Arquivos Descrição Formato
000764046.pdf (293.1Kb) Texto completo (inglês) Adobe PDF Visualizar/abrir

Este item está licenciado na Creative Commons License

Este item aparece na(s) seguinte(s) coleção(ões)


Mostrar registro completo

Percorrer



  • O autor é titular dos direitos autorais dos documentos disponíveis neste repositório e é vedada, nos termos da lei, a comercialização de qualquer espécie sem sua autorização prévia.
    Projeto gráfico elaborado pelo Caixola - Clube de Criação Fabico/UFRGS Powered by DSpace software, Version 1.8.1.