Mostrar registro simples

dc.contributor.authorPiva, Jefferson Pedropt_BR
dc.contributor.authorChatrkaw, Phornlertpt_BR
dc.contributor.authorChoong, Karenpt_BR
dc.contributor.authorFrndova, Helenapt_BR
dc.contributor.authorCox, Peterpt_BR
dc.date.accessioned2012-08-30T01:36:38Zpt_BR
dc.date.issued2000pt_BR
dc.identifier.issn0021-7557pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/54697pt_BR
dc.description.abstractObjetivos: a) avaliar o efeito na oxigenação e ventilação de coelhos artificialmente depletados de surfactante quando submetidos à ventilação mecânica convencional associada à reposição parcial de surfactante exógeno; b) comparar a evolução deste grupo com outro grupo submetido à ventilação de alta freqüência por oscilação (HFO) sem reposição associada de surfactante. Métodos: Vinte coelhos brancos da raça New Zealand, peso de ± 3 kg, foram anestesiados e artificialmente induzidos à depleção de surfactante endógeno através de sucessivas lavagens pulmonares com alíquotas (25 ml/kg) de solução fisiológica, até atingir uma PaO2 menor que 100 mmHg, quando ventilados via traqueostomia no modo de pressão controlada objetivando um volume corrente de 10 ml/kg, com PEEP de 5cm H2O, FiO2 de 100%, freqüência respiratória de 30 mpm, e tempo inspiratório de 0,65 s. Posteriormente, os coelhos foram divididos em (a) grupo CMV+S, submetido à ventilação convencional associada com reposição parcial de surfactante exógeno; (b) grupo HFO submetido à ventilação de alta freqüência por oscilação. Gasometrias arteriais foram coletadas antes da lavagem pulmonar, após a lavagem pulmonar, 15, 60 e 120 minutos após iniciado o tratamento. Os grupos foram comparados utilizando-se o teste t de Student. Resultados: Em ambos grupos a PaO2 (pós lavagem pulmonar) era inferior a 50 mmHg (p = 0,154), subindo aos 15 minutos de tratamento para 254 mmHg (CMV+S) e 288 mmHg (HFO, p = 0,626). Aos 60 e 120 minutos, a PaO2 foi maior (p = 0,001) no grupo HFO (431 e 431 mmHg) quando comparado com o grupo CMV+S, que apresentou queda progressiva (148 e 126 mmHg). Aos 60 minutos a PaCO2 era significativamente menor no grupo do CMV+S (29 versus 41 mmHg). Conclusões: Em modelo animal com SARA a estratégia de ventilação protetora como a HFO, isoladamente, promove uma rápida e persistente melhora na oxigenação, inclusive, com níveis superiores aos obtidos pelos animais submetidos à ventilação mecânica convencional associada à reposição de surfactante.pt_BR
dc.description.abstractObjectives: (a) to evaluate the effect on oxygenation and ventilation of rabbits with induced surfactant depletion when they are submitted to a conventional mechanical ventilation, plus a small dose of exogenous surfactant; (b) to compare this group with another group submitted to a High Frequency Oscillation (HFO) without exogenous surfactant administration. Methods: Twenty New Zealand White rabbits weighing (± 3 kg) were anaesthetized and artificially induced to a endogenous surfactant depletion by successively lung lavage with normal saline (aliquots of 25 ml/kg) until to reach a persistent PaO2 less than 100 mmHg when submitted to a mechanical ventilation in a pressure control mode with a target tidal volume of 10ml/kg, PEEP of 5cm H2O, FiO2 1.0, respiratory rate 30/min, and inspiratory time of 0.65 s. Then the rabbits were divided in (a) CMV+S group, submitted to a conventional mechanical ventilation plus exogenous surfactant replacement; (b) HFO group, submitted to a High Frequency Oscillation Ventilation. Arterial blood gases were measured at control period, post lung lavage, 15, 16 and 120 minutes after treatment started. The groups were compared using Student t test. Results: The post lung lavage PaO2 in both groups was lower than 50mmHg (p = 0.154), increasing after 15 min of treatment to 254 mmHg (CMV+S) and 288 mmHg (HFO, p = 0.626). The PaO2 at 60 and 120 minutes were higher (p = 0.001) in the HFO group (431 e 431 mmHg) when compared with the CMV+S group, which showed a progressive fall (148 e 126 mmHg). At 60 minutes of treatment, the PaCO2 was lower (p = 0.008) in the CMV+S group (29 versus 41 mmHg). Conclusions: In ARDS animal model a protect mechanical ventilation strategy as HFO by itself promotes a fast and persistent increase in the oxygenation, with superior levels than those observed in animals treated with conventional mechanical ventilation plus exogenous surfactant replacement.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.relation.ispartofJornal de pediatria. Porto Alegre. Vol. 76, n. 5 (set./out. 2000), p. 349-356pt_BR
dc.rightsOpen Accessen
dc.subjectSurface-active agentsen
dc.subjectSurfactantes pulmonarespt_BR
dc.subjectArtificial respirationen
dc.subjectRespiração artificialpt_BR
dc.subjectVentiladores mecânicospt_BR
dc.subjectHypoxemiaen
dc.subjectRespiratory insufficiencyen
dc.subjectModelos animais de doençaspt_BR
dc.subjectCoelhospt_BR
dc.titleVentilação de alta freqüência por oscilação comparada a ventilação mecânica convencional associada a reposição de surfactante em coelhospt_BR
dc.title.alternativeHigh frequency oscillation ventilation compared to conventional mechanical ventilation plus exogenous surfactant replacement in rabbits en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000385184pt_BR
dc.type.originNacionalpt_BR